    J Pediatr Orthop. 2007 Sep;27(6):648-52.

    Reliability of popliteal angle measurement: a study in cerebral palsy patients and healthy controls.

    Source

    Center for Rehabilitation, University Medical Center Groningen, The Netherlands.

    Abstract

    The popliteal angle is a widely used clinical measure for hamstring contracture in cerebral palsy (CP) patients and in healthy individuals. The reliability of popliteal angle measurement is being questioned. The aim of this study is to determine the reliability of popliteal angle measurement by means of visual and goniometric assessment.

    METHODS:

    Three different observers measured the popliteal angle in 15 CP patients and 15 healthy volunteers. In each subject, popliteal angles were visually estimated and measured with a blinded goniometer twice by all observers with approximately 1 hour between measurement sessions.

    RESULTS:

    All intraclass correlation coefficients (ICCs) were lower in the CP group compared with healthy controls. The ICC for intraobserver differences was higher than 0.75 for both groups. The ICC for interobserver reliability of visual estimates and goniometric measurements was low for both groups. Intermethod ICC was higher than 0.75 for both groups.

    CONCLUSIONS:

    Measurements in the CP group seemed to be less reliable than measurements in the control group. Intraobserver reliability is reasonable for both groups, but lower in CP patients than in controls. Interobserver reliability of both visual estimates and goniometrical measurements is poor. No significant differences in reliability have been found between visual estimation and goniometric measurement. Because of poor interobserver reliability of popliteal angle measurement, this should not be the only variable in clinical decision making in CP patients.

    PMID:
    17717465
    [PubMed - indexed for MEDLINE]