Display Settings:

Format

Send to:

Choose Destination
    Neurosci Lett. 2007 May 29;419(2):119-24. Epub 2007 May 4.

    Fluorescence imaging study of extracellular zinc at the hippocampal mossy fiber synapse.

    Source

    Department of Biomedical Science, Program in Biological Sciences, Ohio University, Athens, OH 45701, USA.

    Abstract

    Although synaptically released, vesicular Zn(2+) has been proposed to play a neuromodulatory or neuronal signaling role at the mossy fiber-CA3 synapse, Zn(2+) release remains controversial, especially when detected using fluorescent imaging. In the present study, we investigated synaptically released Zn(2+) at the mossy fiber (MF) synapse in rat hippocampal slices using three chemically distinct, fluorescent Zn(2+) indicators. The indicators employed for this study were cell membrane impermeable (or extracellular) Newport Green [K(DZn2+) approximatelly 1 microM] , Zinpyr-4 K(DZn2+) approximately 1 nM and FluoZin-3 K(DZn2+) approximately 15 nM, chosen, in part, for their distinct dissociation constants. Among the three indicators, FluoZin-3 was also sensitive to Ca(2+) K(DCa2+) approximately 200-300 microM which was present in the extracellular medium ([Ca(2+)](o)>2mM). Hippocampal slices loaded with either Newport Green or FluoZin-3 showed increases in fluorescence after electrical stimulation of the mossy fiber pathway. These results are consistent with previous studies suggesting the presence of synaptically released Zn(2+) in the extracellular space during neuronal activities; however, the rise in FluoZin-3 fluorescence observed was complicated by the data that the addition of exogenous Zn(2+) onto FluoZin-3 loaded slices gave little change in fluorescence. In the slices loaded with the high-affinity indicator Zinpyr-4, there was little change in fluorescence after mossy fiber activation by electrical stimulation. Further study revealed that the sensitivity of Zinpyr-4 was mitigated by saturation with Zn(2+) contamination from the slice. These data suggest that the sensitivity and selectivity of a probe may affect individual outcomes in a given experimental system.

    PMID:
    17485170
    [PubMed - indexed for MEDLINE]
    PMCID: PMC2965409
    Free PMC Article

    Images from this publication.See all images (3) Free text

    Figure 2
    Figure 3
    Figure 1

      Supplemental Content

      Click here to read Click here to read

      Recent activity

      Your browsing activity is empty.

      Activity recording is turned off.

      Turn recording back on

      See more...
      Write to the Help Desk