Display Settings:

Format

Send to:

Choose Destination
    J Clin Anesth. 2007 Mar;19(2):125-9.

    Effect of low tidal volume ventilation on atelectasis in patients during general anesthesia: a computed tomographic scan.

    Source

    Department of Anesthesiology and Intensive Care Medicine, Xiangya Hospital, Central Southern University, Changsha, 41008, China.

    Abstract

    STUDY OBJECTIVE:

    To determine whether low tidal ventilation in patients without lung injury results in an increase in the amount of atelectasis and a further impairment of gas exchange during general anesthesia.

    DESIGN:

    Randomized, single-blind study.

    SETTING:

    University hospital.

    PATIENTS:

    16 adult, ASA physical status I and II patients, who were scheduled for elective excision of intracranial lesion.

    INTERVENTIONS:

    Patients were randomly allocated to one of two groups: traditional tidal volume (V(T)) ventilation group (V(T), 10 mL/kg) and low V(T) ventilation group (V(T), 6 mL/kg) after the first computed tomographic (CT) scan.

    MEASUREMENTS AND MAIN RESULTS:

    Atelectasis, as determined by CT and arterial blood gas analysis, was measured before induction, after tracheal intubation, and at the end of operation. After tracheal intubation, CT scan showed atelectasis in both groups. The mean atelectasis area was 4.25 +/- 2.05 cm(2) (3.32% +/- 1.94%) in the traditional V(T) ventilation group and 5.56 +/- 3.21 cm(2) (4.19% +/- 2.31%) in the low V(T) ventilation group. At the end of operation, there was no significant increase in the amount of atelectasis within the two groups. Arterial blood gas analysis showed no differences after tracheal intubation or at the end of operation in either group.

    CONCLUSION:

    Ventilation using low V(T)s does not cause more pulmonary collapse than mechanical ventilation using standard V(T)s.

    PMID:
    17379125
    [PubMed - indexed for MEDLINE]

      Supplemental Content

      Icon for Elsevier Science

      Save items

      loading

      Recent activity

      Your browsing activity is empty.

      Activity recording is turned off.

      Turn recording back on

      See more...
      Write to the Help Desk