Display Settings:

Format

Send to:

Choose Destination
See comment in PubMed Commons below
J Chromatogr A. 2007 Jun 15;1153(1-2):172-85. Epub 2007 Feb 24.

Extraction and clean-up strategies for the analysis of poly- and perfluoroalkyl substances in environmental and human matrices.

Author information

  • 1Institute for Environmental Studies (IVM), Vrije Universiteit, De Boelelaan 1087, 1081 HV Amsterdam, The Netherlands. stefan.van.leeuwen@ivm.falw.vu.nl

Abstract

The rapidly expanding field of per- and polyfluorinated alkyl substances (PFASs) research has resulted in a wide range of analytical methodologies to determine the human and environmental exposure to PFASs. This paper reviews the currently applied techniques for sample pre-treatment, extraction and clean-up for the analysis of ionic and non-ionic PFASs in human and environmental matrices. Solid phase extraction (SPE) is the method of choice for liquid samples (e.g. water, blood, serum, plasma), and may be automated in an on-line set-up for (large volume) sample enrichment and sample clean-up. Prior to SPE, sample pre-treatment (filtration or centrifugation for water or protein precipitation for blood) may be required. Liquid-liquid extraction can also be used for liquid samples (and does not require above mentioned sample pretreatment). Solid-liquid extraction is the commonly applied method for solid matrices (biota, sludge, soil, sediment), but automation options are limited due to contamination from polytetrafluorethylene tubings and parts applied in extraction equipment. Air is generally preconcentrated on XAD-resins sandwiched between polyurethane foam plugs. Clean-up of crude extracts is essential for destruction and removal of lipids and other co-extractives that may interfere in the instrumental determination. SPE, (fluorous) silica column chromatography, dispersive graphitized carbon and destructive methods such as sulphuric acid or KOH treatment can be applied for clean-up of extracts. Care should be taken to avoid contamination (e.g. from sample bottles, filters, equipment) and losses of PFASs (e.g. adsorption, volatilization) during sampling, extraction and clean-up. Storage at -20 degrees C is generally appropriate for conservation of samples.

PMID:
17349649
[PubMed - indexed for MEDLINE]
PubMed Commons home

PubMed Commons

0 comments
How to join PubMed Commons

    Supplemental Content

    Full text links

    Icon for Elsevier Science
    Loading ...
    Write to the Help Desk