J Appl Biomech. 2006 Aug;22(3):234-9.

Measurement of in vivo lumbar intervertebral disc pressure during spinal manipulation: a feasibility study.

Author information

  • 1Palmer Center for Chiropractic Research, Davenport, IA, USA.

Abstract

This paper presents the first reported measurements of lumbar intervertebral disc pressure in vivo during spinal manipulation. A pressure transducer was inserted into the nucleus pulposus of one normal-appearing lumbar disc in an asymptomatic adult volunteer. Pressures were recorded during several body positions and maneuvers, then during spinal manipulation, and lastly during a repetition of the preintervention body positions. Baseline pressures in the prone and side-lying positions measured 110 kPa and 150 kPa, respectively. During the manipulation, pressure rose to a peak of 890 kPa over 250 ms. Immediately following, pressures in the prone and side-lying positions measured 150 kPa and 165 kPa, respectively. These data do not support the hypotheses that manipulation can reduce a herniation by decreasing intradiscal pressure, or cause a herniation by raising pressure to failure levels. Further work may lead to a better understanding of this treatment method.

PMID:
17215555
[PubMed - indexed for MEDLINE]