Display Settings:

Format

Send to:

Choose Destination
We are sorry, but NCBI web applications do not support your browser and may not function properly. More information
    N Engl J Med. 1991 Apr 25;324(17):1156-61.

    Measurement of prostate-specific antigen in serum as a screening test for prostate cancer.

    Source

    Department of Surgery, Washington University School of Medicine, St. Louis, MO.

    Erratum in

    • N Engl J Med 1991 Oct 31;325(18):1324.

    Abstract

    BACKGROUND:

    Prostate-specific antigen (PSA) is secreted exclusively by prostatic epithelial cells, and its serum concentration is increased in men with prostatic disease, including cancer. We evaluated its usefulness in the detection and staging of prostate cancer.

    METHODS:

    We measured serum PSA concentrations in 1653 healthy men 50 or more years old. Those with PSA values greater than or equal to 4.0 micrograms per liter then underwent rectal examination and prostatic ultrasonography. Ultrasound-directed prostatic needle biopsies were performed in the men with abnormal findings on rectal examination, ultrasonography, or both. The results were compared with those in 300 consecutively studied men 50 or more years old who underwent ultrasound-directed biopsy because of symptoms or abnormal findings on rectal examination.

    RESULTS:

    Serum PSA levels ranged from 4.0 to 9.9 micrograms per liter in 6.5 percent of the 1653 men (107). Nineteen of the 85 men in this group (22 percent) who had prostatic biopsies had prostate cancer. Serum PSA levels were 10.0 micrograms per liter or higher in 1.8 percent of the 1653 men (30). Eighteen of the 27 men in this group (67 percent) who had prostatic biopsies had cancer. If rectal examination alone had been used to screen the men who had biopsies, 12 of the 37 cancers (32 percent) would have been missed. If ultrasonography alone had been used to screen these men, 16 of the 37 cancers (43 percent) would have been missed. Serum PSA measurement had the lowest error rate of the tests, and PSA measurement plus rectal examination had the lowest error rate of the two-test combinations.

    CONCLUSIONS:

    The combination of measurement of the serum PSA concentration and rectal examination, with ultrasonography performed in patients with abnormal findings, provides a better method of detecting prostate cancer than rectal examination alone.

    Comment in

    PMID:
    1707140
    [PubMed - indexed for MEDLINE]
    Free full text

      Supplemental Content

      Icon for Atypon

      Save items

      Recent activity

      Your browsing activity is empty.

      Activity recording is turned off.

      Turn recording back on

      See more...
      Write to the Help Desk