Send to:

Choose Destination
See comment in PubMed Commons below
Am J Kidney Dis. 2006 Oct;48(4):596-605.

Comparison of low-dose gentamicin with minocycline as catheter lock solutions in the prevention of catheter-related bacteremia.

Author information

  • 1Division of Nephrology, Henry Ford Hospital, Detroit, MI 48202, USA.



Catheter-restricted antibiotic lock solutions were found to be effective in the prevention of catheter-related bacteremia (CRB), but insufficient data are available about the ideal agent and dose. We hypothesized that a low concentration of gentamicin would be as effective as the high doses studied in the past.


In this prospective, open-labeled, randomized, clinical trial of patients on long-term hemodialysis therapy, patients were randomly assigned to administration of an antibiotic lock solution of gentamicin/citrate (4 mg/mL), minocycline/EDTA, or the control solution of heparin. Patients were followed up until the study end point of CRB was reached or a censoring event occurred. Interim data analysis was performed after 6 months to assess data safety; efficacy was noted and the study was terminated early.


Sixty-two patients were enrolled into the study, evenly distributed in 3 arms, with data from 1 patient excluded from analysis. Seven of 20 patients in the heparin group (4.0 events/1,000 catheter days), 1 of 21 patients in the minocycline group (0.4 events/1,000 catheter days), and none of 20 patients in the gentamicin group developed bacteremia. Results were statistically significant by using 2-tailed Fisher exact test; heparin versus gentamicin, P = 0.008, and heparin versus minocycline, P = 0.020.


Antibiotic lock solutions are superior to the standard heparin lock alone in the prevention of CRBs, and low-dose gentamicin solution has efficacy similar to that of greater concentrations used in previous studies.