    J Laparoendosc Adv Surg Tech A. 2006 Aug;16(4):369-71.

    Laparoscopic removal of a retained intra-abdominal ribbon malleable retractor after 14 years.

    Rodrigues D, Perez NE, Hammer PM, Webber JD.

    Department of Internal Medicine, Harper University Hospital, Wayne State University School of Medicine, Detroit, Michigan 48201, USA. jwebber@dmc.org

    We report a case of the laparoscopic removal of a 33 x 5 cm ribbon malleable retractor retained intra-abdominally for 14 years. Plain films revealed a radiopaque object in the midline abdomen consistent with a metallic device. This was a ribbon malleable retractor which was subsequently removed laparoscopically without complication. Laparoscopic surgery should be considered in the removal of foreign bodies from the abdominal cavity.