Display Settings:

Format

Send to:

Choose Destination
Am J Infect Control. 2006 Aug;34(6):388-93.

Are antiseptic-coated central venous catheters effective in a real-world setting?

Author information

  • 1Department of Internal Medicine, University of Michigan, Ann Arbor, 48109-0376, USA. dborsche@umich.edu

Abstract

BACKGROUND:

Catheter-related bloodstream infections are common, costly, and morbid. Randomized controlled trials indicate that antiseptic-coated central venous catheters reduce infection rates.

OBJECTIVE:

To assess the clinical and economic effectiveness of antiseptic-coated catheters for critically ill patients in a real-world setting.

METHODS:

Central venous catheters coated with chlorhexidine/silver-sulfadiazene were introduced in all patients requiring central venous access in adult intensive care units at the University of Michigan Health System, a large, tertiary care teaching hospital. A pretest-posttest cohort design measured the primary outcome of catheter-related bloodstream infection rate, comparing the 2 years prior to the intervention with the 2 years following the intervention. We also evaluated cost-effectiveness and changes in vancomycin use.

RESULTS:

The intervention was associated with a 4% per month relative reduction in the incidence of catheter-related bloodstream infection, after controlling for the effects of time. Overall, a 35% relative risk reduction (P < .0003) in the catheter-related bloodstream infection rate occurred in the posttest phase. The use of antiseptic-coated catheters reduced costs more than $100,000 annually. Vancomycin use was less in units in which antiseptic catheters were used compared with wards in which these catheters were not used.

CONCLUSION:

Antiseptic-coated catheters appear to be clinically effective and economically efficient in a real-world setting.

PMID:
16877109
[PubMed - indexed for MEDLINE]
PubMed Commons home

PubMed Commons

0 comments
How to join PubMed Commons

    Supplemental Content

    Full text links

    Icon for Elsevier Science
    Loading ...
    Write to the Help Desk