    Am J Clin Pathol. 2006 Jun;125(6):873-82.

    Errors in thyroid gland fine-needle aspiration.

    Source

    Department of Pathology, University of Pittsburgh, School of Medicine, Pittsburgh, PA 15232, USA.

    Abstract

    Scant published data exist on redesigning pathology practice based on error data. In this first step of an Agency for Healthcare Research and Quality patient safety project, we measured the performance metrics of thyroid gland fine-needle aspiration, performed root cause analysis to determine the causes of error, and proposed error-reduction initiatives to address specific errors. Eleven cytologists signed out 1,543 thyroid gland aspirates in 2 years, and surgical pathology follow-up was obtained in 364 patients. Of the 364 patients, 91 (25.0%) had a false-negative diagnosis and 36 (9.9%) a false-positive diagnosis. Root cause analysis showed that major sources of error were pre-analytic (poor specimen quality) and analytic (interpretation of unsatisfactory specimens as nonneoplastic and lack of diagnostic category standardization). We currently are evaluating the effectiveness of error reduction initiatives that target pre-analytic and analytic portions of the diagnostic pathway.