Plot of the data obtained from micropipette aspiration of a POPC lipid vesicle in the high-tension regime at 25°C. The data is presented in the form of the frame tension,
τ (Eq. 3), as a function of the optically resolvable area,
Ap (Eq. 2). The fitting range is limited to
τ ≥ 2 mN/m, which yields the apparent area expansion modulus

. The error bars are estimated by (
δτ/
τ) ∼ (
δR1/
R1) ∼ 1/25 and (
δAp/
Ap) ∼(
δR2/
R2) ∼ 1.5 × 10
−3. The zero frame tension area,
Ap,0, is the intercept of the fitted linear curve and the
x axis.