    Diabetes. 2005 Jul;54(7):1914-25.

    Assessing the predictive accuracy of QUICKI as a surrogate index for insulin sensitivity using a calibration model.

    Chen H, Sullivan G, Quon MJ.

    Diabetes Unit, National Center for Complementary and Alternative Medicine, National Institutes of Health, Building 10, Room 6C-205, 10 Center Dr. MSC 1632, Bethesda, MD 20892-1632, USA.

    The quantitative insulin-sensitivity check index (QUICKI) has an excellent linear correlation with the glucose clamp index of insulin sensitivity (SI(Clamp)) that is better than that of many other surrogate indexes. However, correlation between a surrogate and reference standard may improve as variability between subjects in a cohort increases (i.e., with an increased range of values). Correlation may be excellent even when prediction of reference values by the surrogate is poor. Thus, it is important to evaluate the ability of QUICKI to accurately predict insulin sensitivity as determined by the reference glucose clamp method. In the present study, we used a calibration model to compare the ability of QUICKI and other simple surrogates to predict SI(Clamp). Predictive accuracy was evaluated by both root mean squared error of prediction as well as a more robust leave-one-out cross-validation-type root mean squared error of prediction (CVPE). Based on data from 116 glucose clamps obtained from nonobese, obese, type 2 diabetic, and hypertensive subjects, we found that QUICKI and log (homeostasis model assessment [HOMA]) were both excellent at predicting SI(Clamp) (CVPE = 1.45 and 1.51, respectively) and significantly better than HOMA, 1/HOMA, and fasting insulin (CVPE = 3.17, P < 0.001; 1.67, P < 0.02; and 2.85, P < 0.001, respectively). QUICKI and log(HOMA) also had the narrowest distribution of residuals (measured SI(Clamp) - predicted SI(Clamp)). In a subset of subjects (n = 78) who also underwent a frequently sampled intravenous glucose tolerance test with minimal model analysis, QUICKI was significantly better than the minimal model index of insulin sensitivity (SI(MM)) at predicting SI(Clamp) (CVPE = 1.54 vs. 1.98, P = 0.001). We conclude that QUICKI and log(HOMA) are among the most accurate surrogate indexes for determining insulin sensitivity in humans.

    PMID: 15983190 [PubMed - indexed for MEDLINE]

    Supplemental Content

    Click here to read

    Patient drug information

    • Insulin Injection (Humulin R®, Humulin N®, Humulin 70/30®, ...)

      Insulin injection is used to control blood sugar in people who have type 1 diabetes (condition in which the body does not make insulin and therefore cannot control the amount of sugar in the blood) or in people who have ...