    Singapore Med J. 2005 Jun;46(6):297-301.

    Initial experience in use of fluorine-18-fluorodeoxyglucose positron emission tomography/computed tomography in thyroid carcinoma patients with elevated serum thyroglobulin but negative iodine-131 whole body scans.

    Ong SC, Ng DC, Sundram FX.

    Department of Nuclear Medicine and PET, Singapore General Hospital. gnmosc@sgh.com.sg

    Comment in:

    Abstract

    INTRODUCTION: This study aims to examine the usefulness of fluorine-18-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) in thyroid carcinoma patients with elevated serum thyroglobulin (Tg) but negative iodine-131 (I-131) whole body scans.

    METHODS: 17 patients with differentiated thyroid carcinoma who underwent FDG PET/CT scans were reviewed retrospectively over a period of one year from July 2003 to June 2004. All these patients had completion thyroidectomy and subsequently presented with elevated serum Tg but negative post-therapy I-131 whole body scans. Nine of these patients underwent FDG PET/CT in a hypothyroid state, while the remainder underwent FDG PET/CT while on thyroxine replacement.

    RESULTS: 15 out of 17 PET/CT scans revealed lesions consistent with metastases, giving a sensitivity of 88.2 percent. Four of these patients were amendable to surgical treatment. Two scans were negative.

    CONCLUSION: FDG PET/CT is a sensitive diagnostic tool to detect radioiodine-negative recurrences/metastases in patients with thyroid carcinoma. Our preliminary results are comparable with published results based on PET.

    PMID: 15902358 [PubMed - indexed for MEDLINE]Free Article