Display Settings:

Format

Send to:

Choose Destination
    Plant Physiol. 2005 Feb;137(2):588-601.

    Benchmarking the CATMA microarray. A novel tool for Arabidopsis transcriptome analysis.

    Source

    Department of Electrical Engineering , Faculty of Engineering, Katholieke Universiteit Leuven, B-3001 Heverlee, Belgium.

    Abstract

    Transcript profiling is crucial to study biological systems, and various platforms have been implemented to survey mRNAs at the genome scale. We have assessed the performance of the CATMA microarray designed for Arabidopsis (Arabidopsis thaliana) transcriptome analysis and compared it with the Agilent and Affymetrix commercial platforms. The CATMA array consists of gene-specific sequence tags of 150 to 500 bp, the Agilent (Arabidopsis 2) array of 60mer oligonucleotides, and the Affymetrix gene chip (ATH1) of 25mer oligonucleotide sets. We have matched each probe repertoire with the Arabidopsis genome annotation (The Institute for Genomic Research release 5.0) and determined the correspondence between them. Array performance was analyzed by hybridization with labeled targets derived from eight RNA samples made of shoot total RNA spiked with a calibrated series of 14 control transcripts. CATMA arrays showed the largest dynamic range extending over three to four logs. Agilent and Affymetrix arrays displayed a narrower range, presumably because signal saturation occurred for transcripts at concentrations beyond 1,000 copies per cell. Sensitivity was comparable for all three platforms. For Affymetrix GeneChip data, the RMA software package outperformed Microarray Suite 5.0 for all investigated criteria, confirming that the information provided by the mismatch oligonucleotides has no added value. In addition, taking advantage of replicates in our dataset, we conducted a robust statistical analysis of the platform propensity to yield false positive and false negative differentially expressed genes, and all gave satisfactory results. The results establish the CATMA array as a mature alternative to the Affymetrix and Agilent platforms.

    PMID:
    15710687
    [PubMed - indexed for MEDLINE]
    PMCID:
    PMC1065359
    Free PMC Article

    Images from this publication.See all images (4) Free text

    Figure 2.
    Figure 4.
    Figure 1.
    Figure 3.

      Supplemental Content

      Icon for HighWire Press Icon for PubMed Central

      Save items

      loading

      Recent activity

      Your browsing activity is empty.

      Activity recording is turned off.

      Turn recording back on

      See more...
      Write to the Help Desk