High-sensitivity power Doppler imaging of normal superficial lymph nodes

J Clin Ultrasound. 2004 Jul-Aug;32(6):273-6. doi: 10.1002/jcu.20036.

Abstract

Purpose: This study was conducted to describe the various patterns of vascularity of the normal superficial lymph nodes detected using high-sensitivity power Doppler imaging according to the dimension and anatomic location of the nodes.

Subjects and methods: A total of 712 lymph nodes (416 in the neck, 205 in the groin, and 91 in the axilla) were studied in 118 patients with high-sensitivity Power doppler. Three categories of vascularity were defined: absence of vascularity (type 1), hilar and perihilar vascularity (type 2), and vascularity in the entire node (type 3). The 3 types of vascularity were correlated with the anatomic location and the dimension (maximum transverse diameter) of the nodes.

Results: Type 3 vascularity was found in all lymph nodes with a maximum transverse diameter > 6 mm, in the 67.9% (133/196) of lymph nodes between 4 and 6 mm in diameter, and in 45.7% (42/92) of lymph nodes between 2 and 4 mm in diameter. In lymph nodes with transverse diameters of 2-6 mm, type 3 vascularity was detected in 80.7% (46/57) of the axillary nodes, in 69.0% (87/126) of the inguinal nodes, and in 40.0% (42/105) of the cervical nodes. Type 2 vascularity was seen in 14.2% (101/712) of all examined lymph nodes. The absence of vascularity (type 1) was noted in only 1.9% (8/416) of cervical and 2.0% (4/205) of inguinal nodes.

Conclusions: State-of-the-art power Doppler equipment can demonstrate type 3 vascularity in a high percentage of normal superficial lymph nodes. This pattern of intense, extensive-but harmonious-vascularity must be considered as an indicator of benignity.

MeSH terms

  • Adolescent
  • Adult
  • Aged
  • Aged, 80 and over
  • Child
  • Female
  • Humans
  • Lymph Nodes / blood supply
  • Lymph Nodes / diagnostic imaging*
  • Male
  • Middle Aged
  • Prospective Studies
  • Ultrasonography, Doppler*