J Bone Joint Surg Am. 1992 Dec;74(10):1498-504.

Fractures adjacent to humeral prostheses.

Author information

  • 1Department of Orthopaedic Surgery, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts 02115.

Abstract

In a review of records and radiographs from 1974 through 1988, we identified seven patients who had a humeral fracture after either a total shoulder replacement or a shoulder hemiarthroplasty. All seven patients had complications after the fracture, and five fractures did not unite until an operation was done. All of the fractures that were treated operatively healed without sequelae. Four patients who were managed operatively had satisfactory relief of pain and one had fair relief. One patient who had a non-union refused further treatment for medical reasons. The one fracture that united without operative treatment healed with the tip of the prosthesis outside of the humeral shaft, but persistent pain led to a revision total shoulder replacement. The average time to union after the operation was approximately five months (range, four to seven months). There was a permanent decrease in the motion of the shoulder from preinjury levels in five of the six patients who had union of the fracture.