Format

Send to

Choose Destination
See comment in PubMed Commons below
Med Eng Phys. 2003 Dec;25(10):843-58.

Particle-hemodynamics modeling of the distal end-to-side femoral bypass: effects of graft caliber and graft-end cut.

Author information

  • 1Department of Mechanical and Aerospace Engineering, North Carolina State University, Campus Box 7910, 3211 Broughton Hall, Raleigh, NC 27695-7910, USA.

Abstract

Late-stage occlusions of peripheral synthetic bypass grafts are frequently due to intimal hyperplasia and/or thrombosis at the distal anastomosis, resulting in unacceptably high failure rates. It has been widely established that hemodynamic and blood particle interactions with the vascular surface as well as surgical injury and compliance mismatch are inciting mechanisms capable of eliciting various cellular level responses associated with distal anastomotic intimal hyperplasia (IH) formation. Primary geometric factors influencing anastomotic hemodynamics include the graft-to-artery diameter ratio and graft-hood shape, which are determined by the graft caliber and initial graft-end cut selected by the vascular surgeon. In this study, the particle-hemodynamic effects of graft-end cuts (straight, curved, and S-shaped) and graft-to-artery diameter ratios (2:1 vs. 1.5:1) have been numerically assessed in four common unexpanded anastomotic configurations with respect to vortical flow patterns, wall shear stress based parameters, and platelet interactions with the vascular surface. Sites of significant platelet-wall interactions have been identified by a novel near-wall residence time (NWRT) model, which includes shear stress based factors for platelet activation and endothelial cell expression of anti-thrombogenic compounds. Of the configurations evaluated, straight and curved graft-end cuts with a graft-to-artery diameter ratio of 1.5:1 were found to reduce the particle-hemodynamic potential for IH development at locations critical to flow delivery. Nevertheless, the potential for significant IH occurrence via platelet and/or endothelial response pathways was highly evident in all conventional anastomoses considered, such that a decisively superior configuration was not determined. These results illustrate the need for alternative anastomotic designs with the intent of reducing critical hemodynamic wall parameters and mitigating regions of significant particle-wall interactions.

PMID:
14630472
[PubMed - indexed for MEDLINE]

LinkOut - more resources

Full Text Sources

Other Literature Sources

PubMed Commons home

PubMed Commons

0 comments
How to join PubMed Commons

    Supplemental Content

    Full text links

    Icon for Elsevier Science
    Loading ...
    Write to the Help Desk