    J Occup Environ Med. 2003 Oct;45(10):1068-73.

    Lung function in Pakistani welding workers.

    Source

    Department of Physiology, Hamdard College of Medicine & Dentistry, Hamdard University, Karachi, Pakistan.

    Abstract

    Our objective was to study the effects of welding fumes and their duration of exposure on lung function. This was a matched case-control cross-sectional study of spirometry in 50 nonsmoking manual metal arc welders who work without the benefit of welding fume control ventilation or respiratory protective devices. Welding workers, with exposures longer than 9 years, showed a significant reduction in spirometry (forced expiratory volume in one second [FEV1], FEV1/forced vital capacity [FVC%], and peak expiratory flow [PEF]) relative to controls. Lung function in nonsmoking welding workers is impaired and stratification of results shows a dose-effect of years of welding on lung function. This effect primarily shows an obstructive pattern of airways disease. Preventive measures in developing countries have to be adopted to avert long-term lung damage in welders.