Display Settings:

Format

Send to:

Choose Destination
See comment in PubMed Commons below
Appl Opt. 2003 Aug 1;42(22):4468-79.

Absolute interferometric test of aspheres by use of twin computer-generated holograms.

Author information

  • 1Institut für Technische Optik, Universität Stuttgart, Pfaffenwaldring 9, 70569 Stuttgart, Germany. reichelt@ito.uni-stuttgart.de

Abstract

A complete absolute interferometric test of axially symmetric aspheres is presented. The method is based on a specially designed computer-generated hologram (CGH) that reconstructs an aspherical wave as well as a spherical auxiliary wave. Since both phase functions have the same symmetry and their pattern is simultaneously encoded, we call this type of multiplex hologram a Twin-CGH. The spherical wave is used for calibration. The aberrations of the spherical auxiliary wave are measured absolutely with either a spherical mirror or an absolute test for Fresnel zone plates. Thus the two types of aberration inherent in the CGH can be identified and separated from each other. The errors of the spherical wave can be transferred to those of the aspherical wave. Two different methods thatuse Twin-CGHs for absolute testing of aspheric surfaces are described. Test procedures are explained, equations are derived, and experimental results are presented. A mutual comparison of the two results and a comparison with the established N-position rotation test are given.

PMID:
12916611
[PubMed]
PubMed Commons home

PubMed Commons

0 comments
How to join PubMed Commons

    Supplemental Content

    Full text links

    Icon for Optical Society of America
    Loading ...