[Successful correction with stent-graft of coronary artery rupture after angioplasty]

Angiol Sosud Khir. 2003;9(2):118-21.
[Article in Russian]

Abstract

Rupture and perforation of coronary arteries complicate in average 0.5% of radiosurgical coronary interventions and often are accompanied by serious consequences and high mortality. According to-type of coronary perforation different methods of correction are used, ranging from conservative measures to urgent cardiosurgical interventions. Coronary stent-grafts with 'sandwich' type of construction ore composed from two metal stents and PTFE layer between them. Development of such stents enabled effective radioguided endovascular repair of coronary ruptures. The paper presents the first Russian experience of stout-graft implantation for coronary artery rupture occurred during direct stenting of proximal anterior descending artery and balloon angioplasty in distal segment. The rupture occurred probably because of wall fragility between affected segment and muscular bridge. Stent-graft JoStent 16 mm in length connected with 3-mm balloon was implanted with subsequent complete restitution of blood flow, resolution of pain syndrome and ECG normalization. Echocardiography in operative theatre and one day after surgery showed no intrapericardial fluid. Stent-graft devices for urgent implantation in cases of coronary rupture must be included into obligatory equipment of radiosurgical facilities.

Publication types

  • Case Reports

MeSH terms

  • Adult
  • Angioplasty, Balloon, Coronary* / adverse effects
  • Coronary Angiography
  • Coronary Disease / diagnostic imaging
  • Coronary Disease / therapy*
  • Coronary Vessels / injuries*
  • Echocardiography
  • Electrocardiography
  • Emergencies
  • Follow-Up Studies
  • Humans
  • Male
  • Polytetrafluoroethylene
  • Rupture
  • Stents*
  • Time Factors

Substances

  • Polytetrafluoroethylene