    Eur Radiol. 2003 Aug;13(8):1931-6. Epub 2003 May 29.

    Single breath-hold real-time cine MR imaging: improved temporal resolution using generalized autocalibrating partially parallel acquisition (GRAPPA) algorithm.

    Source

    Department of Clinical Radiology, University of Munich, Klinikum Grosshadern, Marchioninistrasse 15, 81377 Munich, Germany. wintersperger@ikra.med.uni-muenchen.de

    Abstract

    The purpose of this study was to test parallel imaging techniques for improvement of temporal resolution in multislice single breath-hold real-time cine steady-state free precession (SSFP) in comparison with standard segmented single-slice SSFP techniques. Eighteen subjects were examined on a 1.5-T scanner using a multislice real-time cine SSFP technique using the GRAPPA algorithm. Global left ventricular parameters (EDV, ESV, SV, EF) were evaluated and results compared with a standard segmented single-slice SSFP technique. Results for EDV ( r=0.93), ESV ( r=0.99), SV ( r=0.83), and EF ( r=0.99) of real-time multislice SSFP imaging showed a high correlation with results of segmented SSFP acquisitions. Systematic differences between both techniques were statistically non-significant. Single breath-hold multislice techniques using GRAPPA allow for improvement of temporal resolution and for accurate assessment of global left ventricular functional parameters.

    PMID:
    12783177
    [PubMed - indexed for MEDLINE]