Multidetector CT angiography for preoperative evaluation of living laparoscopic kidney donors

AJR Am J Roentgenol. 2003 Jun;180(6):1633-8. doi: 10.2214/ajr.180.6.1801633.

Abstract

Objective: The purpose of this study was to determine the accuracy of multidetector CT (MDCT) angiography as the primary imaging technique in the evaluation of living kidney donors.

Subjects and methods: Seventy-four consecutive living kidney donors (30 men, 44 women; mean age, 41.7 years) who underwent MDCT were evaluated. CT examination was performed with 120 mL of IV contrast material at an injection rate of 3 mL/sec and a pitch of 6. In every case, arterial and venous phase volumetric data sets were acquired at 25 and 55 sec, respectively. Scans were reconstructed at 1-mm intervals for three-dimensional (3D) imaging using a volume-rendering technique. Axial CT images and 3D CT angiography were evaluated prospectively by one reviewer and retrospectively by two reviewers who had no knowledge of surgical results. Surgical correlation for the location of primary and accessory renal arteries, early branching of the renal arteries, and renal vein anomalies was made.

Results: Seventy-two subjects underwent left nephrectomy, and two subjects underwent right nephrectomy because supernumerary left renal arteries were detected on preoperative CT angiography. Eighteen supernumerary renal arteries (two arteries to 16 kidneys and three arteries to one kidney) to 74 kidneys underwent nephrectomy. CT and surgical findings agreed in 93% of subjects (the average of three reviewers; range, 89-97%). Two small accessory renal arteries were missed by all three reviewers. Those arteries were diminutive and were thought to be insignificant by the surgeons. Early branching of the renal arteries was shown in 14 arteries, and CT and surgical findings agreed in 96% (the average of three reviewers; range, 93-97%). Renal vein anomalies were present in eight subjects, and CT and surgical findings agreed in 99% of the cases (range, 96-100%).

Conclusion: MDCT angiography is highly accurate for detecting vascular anomalies and providing anatomic information for laparoscopic living donor nephrectomy.

Publication types

  • Validation Study

MeSH terms

  • Adult
  • Angiography*
  • Female
  • Humans
  • Kidney Diseases / diagnostic imaging*
  • Kidney Diseases / surgery*
  • Kidney Transplantation*
  • Laparoscopy*
  • Living Donors*
  • Male
  • Middle Aged
  • Preoperative Care*
  • Renal Artery / abnormalities*
  • Renal Artery / diagnostic imaging*
  • Renal Veins / abnormalities*
  • Renal Veins / diagnostic imaging*
  • Reproducibility of Results
  • Sensitivity and Specificity
  • Severity of Illness Index
  • Tomography, X-Ray Computed*