    Biomed Environ Sci. 2002 Dec;15(4):283-90.

    Study of low-intensity 2450-MHz microwave exposure enhancing the genotoxic effects of mitomycin C using micronucleus test and comet assay in vitro.

    Zhang MB, He JL, Jin LF, Lu DQ.

    Institute of Occupational and Environmental Health, Medical College of Zhejiang University, Hangzhou 310031, Zhejiang, China.

    OBJECTIVE: To determine the interaction between 2450-MHz microwaves (MW) radiation and mitomycin C (MMC). METHODS: The synergistic genotoxic effects of low-intensity 2450-MHz microwave and MMC on human lymphocytes were studied using single cell gel electrophoresis (SCGE) assay (comet assay) and cytokinesis-blocked micronucleus (CBMN) test in vitro. The whole blood cells from a male donor and a female donor were either only exposed to 2450-MHz microwaves (5.0 mW/cm2) for 2 h or only exposed to MMC (0.0125 microgram/mL, 0.025 microgram/mL and 0.1 microgram/mL) for 24 h; and the samples were exposed to MMC for 24 h after exposure to MW for 2 h. RESULTS: In the comet assay, the comet lengths (29.1 microns and 25.9 microns) of MW were not significantly longer than those (26.3 microns and 24.1 microns) of controls (P > 0.05). The comet lengths (57.4 microns, 68.9 microns, 91.4 microns, 150.6 microns, 71.7 microns, 100.1 microns, 145.1 microns) of 4 MMC groups were significantly longer than those of controls (P < 0.01). The comet lengths (59.1 microns, 92.3 microns, 124.5 microns, 182.7 microns and 57.4 microns, 85.5 microns, 137.5 microns, 178.3 microns) of 4 MW plus MMC groups were significantly longer than those of controls too (P < 0.01). The comet lengths of MW plus MMC groups were significantly longer than those of the corresponding MMC doses (P < 0.05 or P < 0.01) when the doses of MMC were > or = 0.025 microgram/mL. In the CBMN, the micronucleated cell (MNC) rates of MW were 5@1000 and 6@1000, which showed no difference compared with those (4@1000 and 4@1000) of controls (P > 0.05). The MNC rates of 4 MMC groups were 8@1000, 9@1000, 14@1000, 23@1000 and 8@1000, 8@1000, 16@1000, 30@1000 respectively. When the doses of MMC were > or = 0.05 microgram/mL, MNC rates of MMC were higher than those of controls (P < 0.05). MNC rates of 4 MW plus MMC groups were 12@1000, 13@1000, 20@1000, 32@1000 and 8@1000, 9@1000, 23@1000, 40@1000. When the doses of MMC were > or = 0.05 microgram/mL, MNC rates of MW plus MMC groups were much higher than those of controls (P < 0.01). MNC rates of 4 MW plus MMC groups were not significantly higher than those of the corresponding MMC doses. CONCLUSION: The low-intensity 2450-MHz microwave radiation can not induce DNA and chromosome damage, but can increase DNA damage effect induced by MMC in comet assay.

    PMID: 12642984 [PubMed - indexed for MEDLINE]

    Supplemental Content

    Click here to read

    Patient drug information

    • Mitomycin (Mutamycin®)

      Your doctor has ordered the drug mitomycin to help treat your illness. The drug is given by injection into a vein.