Display Settings:

Format

Send to:

Choose Destination
See comment in PubMed Commons below
Appl Opt. 2003 Jan 10;42(2):175-80.

Planar reflection grating lens for compact spectroscopic imaging system.

Author information

  • 1Department of Electronics and Information Science, Kyoto Institute of Technology, Matsugasaki, Sakyo-ku, Kyoto 606-8585, Japan.

Abstract

A compact spectroscopic imaging device consisting of a planar reflection grating lens, a probe fiber array, and a two-dimensional image sensor was proposed and discussed. Reflected or luminescent lights from a subject are coupled to the probe fibers, guided to fiber output ends, radiated into the air, diffracted by the grating lens with wavelength-dependent angle, and focused onto lines on the image sensor. Two-dimensional intensity distribution on the image sensor can give one-dimensional spectrum distribution along a specified direction. A grating lens was designed with a fiber array and a CCD image sensor for 100-nm wavelength range and 10-mm fiber array width. A spectral resolution of 5 nm and a spatial resolution of 0.25 mm were experimentally confirmed.