Histopathological correlation of corneal diseases with optical coherence tomography

Graefes Arch Clin Exp Ophthalmol. 2002 Sep;240(9):727-34. doi: 10.1007/s00417-002-0518-3. Epub 2002 Aug 24.

Abstract

Purpose: To correlate the cross-sectional images of corneal diseases obtained by optical coherence tomography (OCT) with light microscopy (LM) to determine the corneal components represented in OCT images.

Methods: In a prospective comparative tissue study clinicopathological correlations of six patients with pseudophakic bullous keratopathy ( n=3), advanced keratoconus ( n=1), persistent epithelial defect with corneal thinning ( n=1), and retrocorneal membrane ( n=1) were included. Immediately before a planned penetrating keratoplasty (PKP) noncontact slitlamp-adapted OCT of the cornea was performed. After PKP and following standard histological processing the specimens were examined under LM to compare qualitatively the morphology, and quantitatively the morphometry at selected corneal locations.

Results: The cross-sectional optical-reflectivity profiles enabled the reproducible morphological evaluation of the corneal structures and changes. Layers of relative high reflectivity corresponded to the anterior corneal surface and internal stromal layers. In contrast, the deeper corneal epithelial layer demonstrated relative low reflectivity by OCT. An increase in light reflectivity corresponded to corneal scarring, irregularities of the corneal lamellae, and deposition of basal membrane material. Low signal intensity was particularly due to fluid accumulations and shadowing. The most prominent changes were caused by corneal scars or edematous tissue. The morphometric analysis with OCT revealed, in this study, thickness measurements ranging from 31 to 902 micro m. Although the mean OCT thickness values were up to 9% ( P=0.014) higher than those derived from LM, there was a significant positive correlation (r=0.94; P<0.001) between corneal OCT and the light-microscopic measurements.

Conclusion: Noncontact slitlamp-adapted corneal OCT revealed a good correlation with histological sections. The differences noted were partly related to shrinking processes during preparation. Thus, with certain limitations, OCT allows a non-invasive optical biopsy of pathological structures in corneal diseases.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Aged, 80 and over
  • Cornea / pathology
  • Corneal Diseases / pathology*
  • Corneal Diseases / surgery
  • Humans
  • Interferometry
  • Keratoplasty, Penetrating / pathology*
  • Light
  • Middle Aged
  • Prospective Studies
  • Tomography / methods