Display Settings:

Format

Send to:

Choose Destination

    J Chromatogr B Analyt Technol Biomed Life Sci. 2002 Jan 5;766(1):175-9.

    Rapid and simple high-performance liquid chromatographic assay for the determination of metformin in human plasma and breast milk.

    Zhang M, Moore GA, Lever M, Gardiner SJ, Kirkpatrick CM, Begg EJ.

    Department of Clinical Pharmacology, Christchurch Hospital, New Zealand. mei.zhang@cdhb.govt.nz

    A rapid and simple high-performance liquid chromatographic (HPLC) assay for the determination of metformin in human plasma and breast milk is described. After proteins were precipitated with acetonitrile, metformin and the internal standard buformin were resolved on a cation-exchange column and detected by UV detection at 236 nm. Standard curves were linear over the concentration range 20.0-4000 microg/l. Intra- and inter-day coefficients of variation were <9.0% and the limit of quantification was around 20 microg/l.

    PMID: 11824394 [PubMed - indexed for MEDLINE]