A fence line noble gas monitoring system for nuclear power plants

Radiat Prot Dosimetry. 2001;95(3):249-56. doi: 10.1093/oxfordjournals.rpd.a006548.

Abstract

A noble gas monitoring system has been installed at Ontario Power Generation's Pickering Nuclear Generating Station (PNGS) near Toronto, Canada. This monitoring system allows a direct measure of air kerma from external radiation instead of calculating this based on plant emission data and meteorological models. This has resulted in a reduction in the reported effective dose from external radiation by a factor of at least ten. The system consists of nine self-contained units, each with a 7.6 cm x 7.6 cm (3 inch x 3 inch) NaI(TI) detector that is calibrated for air kerma. The 512-channel gamma ray spectral information is downloaded daily from each unit to a central computer where the data are stored and processed. A spectral stripping procedure is used to remove natural background variations from the spectral windows used to monitor xenon-133 (133Xe), xenon-135 (135Xe), argon-41 (41Ar), and skyshine radiation from the use of radiography sources. Typical monthly minimum detection limits in air kerma are 0.3 nGy for 133Xe, 0.7 nGy for 35Xe, 3 nGy for 41Ar and 2 nGy for skyshine radiation. Based on 9 months of continuous operation, the annualised air kerma due to 133Xe, 135Xe and 41Ar and skyshine radiation were 7 nGy, 8 nGy, 26 nGy and 107 nGy respectively.

MeSH terms

  • Air
  • Background Radiation
  • Calibration
  • Monte Carlo Method
  • Noble Gases / analysis*
  • Nuclear Reactors
  • Power Plants
  • Radiation Monitoring / methods*
  • Signal Processing, Computer-Assisted
  • Spectrometry, Gamma

Substances

  • Noble Gases