Display Settings:

Format

Send to:

Choose Destination

    Diabetes. 2001 Mar;50(3):565-72.

    Effect of glucagon-like peptide-1(7-36)-amide on initial splanchnic glucose uptake and insulin action in humans with type 1 diabetes.

    Vella A, Shah P, Basu R, Basu A, Camilleri M, Schwenk FW, Holst JJ, Rizza RA.

    Department of Internal Medicine, Mayo Clinic and Foundation, Rochester, Minnesota 55905, USA.

    In vitro studies indicate that glucagon-like peptide-1(7-36)-amide (GLP-1) can enhance hepatic glucose uptake. To determine whether GLP-1 increases splanchnic glucose uptake in humans, we studied seven subjects with type 1 diabetes on two occasions. On both occasions, glucose was maintained at approximately 5.5 mmo/l during the night using a variable insulin infusion. On the morning of the study, a somatostatin, glucagon, and growth hormone infusion was started to maintain basal hormone levels. Glucose (containing [3H]glucose) was infused via an intraduodenal tube at a rate of 20 micromol.kg(-1).min(-1). Insulin concentrations were increased to approximately 500 pmol/l while glucose was clamped at approximately 8.8 mmol/l for the next 4 h by means of a variable intravenous glucose infusion labeled with [6,6-2H2]glucose. Surprisingly, the systemic appearance of intraduodenally infused glucose was higher (P = 0.01) during GLP-1 infusion than saline infusion, indicating a lower (P < 0.05) rate of initial splanchnic glucose uptake (1.4 +/- 1.5 vs. 4.8 +/- 0.8 micromol.kg(-1).min(-1)). On the other hand, flux through the hepatic uridine-diphosphate- glucose pool did not differ between study days (14.2 +/- 5.5 vs. 13.0 +/- 4.2 micromol.kg(-1).min(-1)), implying equivalent rates of glycogen synthesis. GLP-1 also impaired (P < 0.05) insulin-induced suppression of endogenous glucose production (6.9 +/- 2.9 vs. 1.3 +/- 1.4 micromol.kg(-1).min(-1)), but caused a time-dependent increase (P < 0.01) in glucose disappearance (93.7 +/- 10.0 vs. 69.3 +/- 6.3 micromol.kg(-1).min(-1); P < 0.01) that was evident only during the final hour of study. We conclude that in the presence of hyperglycemia, hyperinsulinemia, and enterally delivered glucose, GLP-1 increases total body but not splanchnic glucose uptake in humans with type 1 diabetes.

    PMID: 11246876 [PubMed - indexed for MEDLINE]

    Supplemental Content

    Click here to read

    Patient drug information

    • Glucagon (GlucaGen Diagnostic Kit®)

      Glucagon is a hormone produced in the pancreas. Glucagon is used to raise very low blood sugar. Glucagon is also used in diagnostic testing of the stomach and other digestive organs.