1: Radiology. 2001 Jan;218(1):138-43.Click here to read Links
Comment in:
Radiology. 2002 May;223(2):586-7; author reply 587.

Carotid artery: elliptic centric contrast-enhanced MR angiography compared with conventional angiography.

Department of Diagnostic Radiology, Mayo Clinic and Foundation, 200 1st St SW, Rochester, MN 55905, USA. jhuston@mayo.edu

PURPOSE: To determine the accuracy of elliptic centric contrast material-enhanced magnetic resonance (MR) angiography by using conventional angiography as the reference standard. MATERIALS AND METHODS: Fifty patients were examined prospectively with contrast-enhanced MR angiography and conventional angiography. The two examinations were performed within 1 week of each other. Two patients underwent conventional angiography of only one carotid artery, which yielded 98 arteries for comparison. RESULTS: With conventional angiography as the reference standard and by using a 70% threshold for internal carotid arterial diameter stenosis, maximum intensity projection (MIP) images had a sensitivity of 93.3%, specificity of 85.1%, and accuracy of 87.6%, whereas reformatted transverse source images had a sensitivity of 83.3%, specificity of 97.0%, and accuracy of 92.8%. Interobserver variability for conventional angiograms was 0.97, for MIP images was 0.91, and for source images was 0.90. The contrast-enhanced MR angiographic technique had a sensitivity of 88.9% and specificity of 58.1% for the presence of irregularity and/or ulceration. All 50 examinations were triggered appropriately so that minimal or no venous signal intensity was depicted. CONCLUSION: Contrast-enhanced elliptic centric three-dimensional MR angiography offers high-spatial-resolution, venous-suppressed images of the carotid arteries that appear to be adequate to replace conventional angiography in most patients examined prior to carotid endarterectomy.

PMID: 11152792 [PubMed - indexed for MEDLINE]