Format

Send to:

Choose Destination
See comment in PubMed Commons below
Clin Biomech (Bristol, Avon). 2001 Jan;16(1):28-37.

Intervertebral disc herniation: studies on a porcine model exposed to highly repetitive flexion/extension motion with compressive force.

Author information

  • 1Occupational Biomechanics and Safety Laboratories, Faculty of Applied Health Sciences, Department of Kinesiology, University of Waterloo, Ont., N2L 3G1, Waterloo, Canada.

Abstract

OBJECTIVE:

To determine whether repeated motion with low magnitude joint forces, and flexion/extension moments consistently produce herniation in a non-degenerated, controlled porcine spine motion segment.

DESIGN:

Combined loading (flexion/extension motions and compressive forces) was applied to in vitro porcine functional spinal units. Biomechanical and radiographic characteristics were documented.

BACKGROUND:

While most studies performed in vitro have examined uniaxial or fixed position loading to older specimens, there have been few studies that have examined whether 'healthy' intervertebral discs can be injured by low magnitude repeated combined loading.

METHODS:

Porcine cervical spine motion segments (C3-C4) were mounted in a custom jig which applied axial compressive loads with pure flexion/extension moments. Dynamic testing was conducted to a maximum of 86400 bending cycles at a rate of 1 Hz with simultaneous torques, angular rotations, axial deformations recorded for the duration of the test.

RESULTS:

Herniation (posterior and posterior-lateral regions of the annulus) occurred with relatively modest joint compression but with highly repetitive flexion/extension moments. Increased magnitudes of axial compressive force resulted in more frequent and more severe disc injuries.

CONCLUSIONS:

The results support the notion that intervertebral disc herniation may be more linked to repeated flexion extension motions than applied joint compression, at least with younger, non-degenerated specimens. Relevance. While intervertebral disc herniations are observed clinically, consistent reproduction of this injury in the laboratory has been elusive. This study was designed to examine the biomechanical response and failure mechanics of spine motion segments to highly repetitive low magnitude complex loading.

PMID:
11114441
[PubMed - indexed for MEDLINE]
PubMed Commons home

PubMed Commons

0 comments
How to join PubMed Commons

    Supplemental Content

    Full text links

    Icon for Elsevier Science
    Loading ...
    Write to the Help Desk