    Arch Ophthalmol. 2000 Nov;118(11):1509-13.

    Baerveldt drainage implants in eyes with a preexisting scleral buckle.

    Source

    Department of Opthalmology, Bascom Palmer Eye Institute, University of Miami School of Medicine, PO Box 016880, Miami, FL 33101, USA. iscott@bpei.med.miami.edu.

    Abstract

    OBJECTIVE:

    To describe the surgical insertion of a Baerveldt drainage implant and postoperative visual acuity and intraocular pressure (IOP) outcomes in patients with a preexisting scleral buckle.

    METHODS:

    Medical records of all patients with a preexisting scleral buckle who underwent insertion of a Baerveldt drainage implant at Bascom Palmer Eye Institute, Miami, Fla, from January 1, 1994, through December 31, 1998, were reviewed. Outcome measures included visual acuity and IOP at 1 year.

    RESULTS:

    At 1 year postoperatively, 14 (88%) of 16 patients had stable or improved visual acuity. Preoperatively, mean IOP was 30.9 mm Hg and the mean number of antiglaucoma medications was 3.4; at 1 year postoperatively, mean IOP was 12.0 mm Hg and the mean number of antiglaucoma medications was 0.8 (P<.001). Nine patients (56%) achieved an IOP of greater than 5 and no greater than 21 mm Hg without medication, and an additional 7 (44%) achieved this level of IOP control with medication. No patient required further surgery for uncontrolled IOP during the follow-up interval, which ranged from 19. 1 to 45.5 months.

    CONCLUSION:

    Baerveldt drainage device insertion behind or over a preexisting encircling band is often successful in managing refractory glaucoma in patients who have undergone previous scleral buckling procedures. Arch Ophthalmol. 2000;118:1509-1513

    PMID:
    11074807
    [PubMed - indexed for MEDLINE]