Am J Ophthalmol. 2000 Jun;129(6):715-22.

Effect of corneal polarization axis on assessment of retinal nerve fiber layer thickness by scanning laser polarimetry.

Author information

  • 1Department of Ophthalmology, University of Miami School of Medicine, Bascom Palmer Eye Institute, Miami, Florida 33418, USA. dgreenfield@bpei.med.miami.edu

Abstract

PURPOSE:

Scanning laser polarimetry uses an anterior segment compensating device that assumes a fixed axis of corneal birefringence, which we call the corneal polarization axis. The purpose of this investigation was to establish the distribution of corneal polarization axes among a population of normal eyes and to evaluate the relationship between corneal polarization axis and posterior segment retardation.

METHODS:

We constructed a noninvasive slit lamp-mounted device incorporating two crossed linear polarizers and an optical retarder in order to measure the slow axis of corneal birefringence. Normal subjects underwent corneal polarization axis measurement. A subset of eyes underwent scanning laser polarimetry of the peripapillary retinal nerve fiber layer (n = 32) and macula (n = 29), and retardation measurements were evaluated in each group.

RESULTS:

One hundred eighteen eyes of 63 normal subjects (35 female, 28 male) underwent corneal polarization axis measurement (mean age, 45.5 +/- 17.1 years). Six eyes (5.1%) demonstrated unmeasurable corneal polarization. In the remaining 112 eyes, the mode of the corneal polarization axis distribution was 10 to 20 degrees nasally downward (range, 90 degrees nasally downward to 54 degrees nasally upward). A significant (P <.0001) correlation was observed between fellow eyes (R(2) =.52), with a mean difference of 11.2 +/- 10.5 degrees (range, 0-52 degrees). Corneal polarization axis was significantly associated (R(2) =.52-.84) with retinal nerve fiber layer and macula summary retardation parameters (average thickness, ellipse average, superior and inferior average, superior and total integral; P <.0001 for all groups).

CONCLUSIONS:

The mean corneal polarization axis among normal corneas is nasally downward; however, considerable intraindividual and interindividual variability exists. The linear relationship between corneal polarization axis and posterior segment retardation parameters is responsible, in part, for the wide distribution of retinal nerve fiber layer thickness data generated by scanning laser polarimetry.

Comment in

PMID:
10926978
[PubMed - indexed for MEDLINE]