J Digit Imaging. 2000 May;13(2 Suppl 1):45-8.

Radiologist's clinical information review workstation interfaced with digital dictation system.

Author information

  • 1Division of Diagnostic Imaging, University of Texas M.D. Anderson Cancer Center, Houston 77030, USA. kmcenery@mdanderson.org

Abstract

Efficient access to information systems integrated into the radiologist's interpretation workflow will result in a more informed radiologist, with an enhanced capability to render an accurate interpretation. We describe our implementation of radStation, a radiologist's clinical information review workstation that combines a digital dictation station with a clinical information display. radStation uses client software distributed to the radiologist's workstation and central server software, both running Windows NT (Microsoft, Redmond, WA). The client system has integrated digital dictation software. The bar-code microphone (Boomerang, Dictaphone Corp, Stratford, CT) also serves as a computer input device forwarding the procedure's accession number to the server software. This initiates multiple queries to available legacy databases, including the radiology information system (RIS), laboratory information system, clinic notes, hospital discharge, and operative report system. The three-tier architecture then returns the clinical results to the radStation client for display. At the conclusion of the dictation, the digital voice file is transferred to the dictation server and the client notifies the RIS to update the examination status. The system is efficient in its information retrieval, with queries displayed in about 1 second. The radStation client requires less than 5 minutes of radiologist training in its operation, given that its control interface integrates with the well-learned dictation process. The telephone-based dictation system, which this new system replaced, remains available as a back-up system in the event of an unexpected digital dictation system failure. This system is well accepted and valued by the radiologists. The system interface is quickly mastered. The system does not interrupt dictation workflow with the display of all information initiated with examination bar-coding. This system's features could become an accepted model as a standard tool for radiologists.

PMID:
10847361
[PubMed - indexed for MEDLINE]
PMCID:
PMC3453296
Free PMC Article
PubMed Commons home

PubMed Commons

0 comments
How to join PubMed Commons

    Supplemental Content

    Icon for PubMed Central
    Loading ...
    Write to the Help Desk