Infect Control Hosp Epidemiol. 1999 Sep;20(9):626-8.

Bacterial contamination of hospital physicians' stethoscopes.

Author information

  • 1Hôpital Saint Joseph, Paris, France.

Abstract

Because stethoscopes might be potential vectors of nosocomial infections, this study, conducted in a 450-bed general hospital, was devised to evaluate the bacterial contamination of stethoscopes; bacterial survival on stethoscope membranes; the kinetics of the bacterial load on stethoscope membranes during clinical use; and the efficacy of 70% alcohol or liquid soap for membrane disinfection. Among the 355 stethoscopes tested, 234 carried > or =2 different bacterial species; 31 carried potentially pathogenic bacteria. Although some bacteria deposited onto membranes could survive 6 to 18 hours, none survived after disinfection.