|
|
J Clin Pathol. 1992 April; 45(4): 328–331. | PMCID: PMC495274 |
Radioimmunoassay that measures serum vitamin B12. J. J. O'Sullivan, R. J. Leeming, S. S. Lynch, and A. Pollock Department of Haematology, General Hospital, Birmingham. Abstract AIMS: To develop a specific radioimmunoassay for the routine determination of serum vitamin B12. METHODS: Antisera were raised in rabbits by immunisation with the monocarboxylic acid derivative of cyanocobalamin coupled to human serum albumin. Antibody titres and affinities were determined and the antiserum giving the highest binding affinity constant, Ka, was used to develop the assay protocol. Donkey-anti-rabbit gamma globulin-coated magnetisable particles were used to separate the bound from free vitamin B12. The considerable cobalamin binding capacity of human serum was destroyed by autoclaving in acetate-cyanide buffer. Sixty samples were assayed by the radioimmunoassay (RIA) and the Lactobacillus leichmannii assay. Recovery and cross-reactivity experiments were performed. RESULTS: Final rabbit antibody titres varied from 1/20,000 to 1/188,000. Scatchard plots did not correlate with the antibody titres. The Ka values varied from 2.6 to 6.7 x 10(10) litres/mol. For maximum sensitivity the highest Ka (titre 1/66,000) was chosen. A tracer concentration of 22 pmol/l, an antiserum dilution of 1/100,000, and a sample volume of 0.1 ml were used. At an antiserum dilution of 1 in 100,000 the cyanocobalamin binding of the rabbit serum was diluted out. The assay showed excellent correlation with the microbiological assay, with 100% recovery of added vitamin B12. Levels of cross-reactivity for dicyanide cobinamide and hydroxocobalamin were 9.8 and 8.1%, respectively. CONCLUSIONS: The development of this immunoassay permits the measurement of serum vitamin B12 without important interference from cobalamin analogues, related corrinoids, and non-specific binders. Full text Full text is available as a scanned copy of the original print version. Get a printable copy (PDF file) of the complete article (768K), or click on a page image below to browse page by page. Links to PubMed are also available for Selected References. These references are in PubMed. This may not be the complete list of references from this article. - ROSS GIM. Vitamin B12 assay in body fluids. Nature. 1950 Aug 12;166(4215):270–271. [PubMed]
- ROSS GIM. Vitamin B12 assay in body fluids using Euglena gracilis. J Clin Pathol. 1952 Aug;5(3):250–256. [PubMed]
- ANDERSON BB. INVESTIGATIONS INTO THE EUGLENA METHOD FOR THE ASSAY OF THE VITAMIN B12 IN SERUM. J Clin Pathol. 1964 Jan;17:14–26. [PubMed]
- ROSENTHAL HL, SARETT HP. The determination of vitamin B12 activity in human serum. J Biol Chem. 1952 Nov;199(1):433–442. [PubMed]
- SPRAY GH. An improved method for the rapid estimation of vitamin B12 in serum. Clin Sci (Lond). 1955 Nov;14(4):661–667. [PubMed]
- FORD JE. The microbiological assay of vitamin B12; the specificity of the requirement of Ochromonas malhamensis for cyanocobalamin. Br J Nutr. 1953;7(4):299–306. [PubMed]
- DAVIS BD, MINGIOLI ES. Mutants of Escherichia coli requiring methionine or vitamin B12. J Bacteriol. 1950 Jul;60(1):17–28. [PubMed]
- Sourial NA. Use of an improved E. coli method for the measurement of cobalamin in serum: comparison with the E. gracilis assay results. J Clin Pathol. 1981 Apr;34(4):351–356. [PubMed]
- Powell DE, Thomas JH, Mandal AR, Dignam CT. Effect of drugs on vitamin B 12 levels obtained using the Lactobacillus leichmanii method. J Clin Pathol. 1969 Nov;22(6):672–676. [PubMed]
- Matthews DM, Gunasegaram R, Linnell JC. Results with radioisotopic assay of serum B12 using serum binding agent. J Clin Pathol. 1967 Sep;20(5):683–686. [PubMed]
- Britt RP, Bolton FG, Cull AC, Spray GH. Experience with a simplified method of radio-isotopic assay of serum vitamin B 12. Br J Haematol. 1969 May;16(5):457–464. [PubMed]
- Rothenberg SP. A radioassay for serum B12 using unsaturated transcobalamin I as the B12 binding protein. Blood. 1968 Jan;31(1):44–54. [PubMed]
- Carmel R, Coltman CA., Jr Radioassay for serum vitamin B12 with the use of saliva as the vitamin B12 binder. J Lab Clin Med. 1969 Dec;74(6):967–975. [PubMed]
- Green R, Newmark PA, Musso AM, Mollin DL. The use of chicken serum for measurement of serum vitamin B12 concentration by radioisotope dilution: discription of method and comparison with microbiological assay results. Br J Haematol. 1974 Jul;27(3):507–526. [PubMed]
- LAU KS, GOTTLIEB C, WASSERMAN LR, HERBERT V. MEASUREMENT OF SERUM VITAMIN B12 LEVEL USING RADIOISOTOPE DILUTION AND COATED CHARCOAL. Blood. 1965 Aug;26:202–214. [PubMed]
- Liu YK, Sullivan LW. An improved radioisotope dilution assay for serum vitamin B12 using hemoglobin-coated charcoal. Blood. 1972 Mar;39(3):426–432. [PubMed]
- ROTHENBERG SP. RADIOASSAY OF SERUM VITAMIN B12 BY QUANTITATING THE COMPETITION BETWEEN CO57B12 AND UNLABELED B12 FOR THE BINDING SITES OF INTRINSIC FACTOR. J Clin Invest. 1963 Sep;42:1391–1398. [PubMed]
- Wagstaff M, Broughton A. A simple routine radioisotope method for the estimation of serum vitamin B12 using DEAE cellulose and human serum binding agent. Br J Haematol. 1971 Nov;21(5):581–593. [PubMed]
- Muir M, Chanarin I. Solid-phase vitamin B12 assays using polyacrylamide-bound intrinsic factor and polyacrylamide-bound R-binder. Br J Haematol. 1983 Mar;53(3):423–435. [PubMed]
- Chanarin I, Muir M. Demonstration of vitamin B12 analogues in human sera not detected by microbiological assay. Br J Haematol. 1982 May;51(1):171–173. [PubMed]
- Jacobs MR, Koornhof HJ, Robins-Browne RM, Stevenson CM, Vermaak ZA, Freiman I, Miller GB, Witcomb MA, Isaäcson M, Ward JI, Austrian R. Emergence of multiply resistant pneumococci. N Engl J Med. 1978 Oct 5;299(14):735–740. [PubMed]
- Cooper BA, Whitehead VM. Evidence that some patients with pernicious anemia are not recognized by radiodilution assay for cobalamin in serum. N Engl J Med. 1978 Oct 12;299(15):816–818. [PubMed]
- Frenkel EP, Kitchens RL, Prough R. High-performance liquid chromatographic separation of cobalamins. J Chromatogr. 1979 Jul 1;174(2):393–400. [PubMed]
- Binder M, Kolhouse JF, Van Horne KC, Allen RH. High-pressure liquid chromatography of cobalamins and cobalamin analogs. Anal Biochem. 1982 Sep 15;125(2):253–258. [PubMed]
- Gershman H, Nathanson N, Abeles RH, Levine L. Production and specificity of antibodies to B 12 derivatives. Arch Biochem Biophys. 1972 Nov;153(1):407–409. [PubMed]
- van de Wiel DF, Goedemans WT, Woldring MG. Production and purification of antibody against protein--vitamin B12 conjugates for radioimmunoassay purposes. Clin Chim Acta. 1974 Oct 30;56(2):143–149. [PubMed]
- Endres DB, Painter K, Niswender GD. A solid-phase radioimmunoassay for vitamin B12 in serum, with use of radioiodinated tyrosine methyl ester of vitamin B12. Clin Chem. 1978 Mar;24(3):460–465. [PubMed]
- Rothenberg SP, Marcoullis GP, Schwarz S, Lader E. Measurement of cyanocobalamin in serum by a specific radioimmunoassay. J Lab Clin Med. 1984 Jun;103(6):959–972. [PubMed]
- Quadros EV, Rothenberg SP, Polu S. A specific radioimmunoassay for 5'-deoxyadenosyl cobalamin in serum. Br J Haematol. 1988 Aug;69(4):551–557. [PubMed]
- Ahrenstedt SS, Thorell JI. The production of antibodies to vitamin B-12. Clin Chim Acta. 1979 Aug 1;95(3):419–423. [PubMed]
|