AIMS: To establish criteria of adequacy for bone marrow trephine biopsy specimens and to audit the quality of trephines performed at the Christie Hospital, Manchester. METHODS: Trephines (n = 767) performed over 12 months were reviewed. Their lengths, and the lengths of their constituent parts (soft tissue, cortex, crushed marrow and interpretable marrow) were measured. The mean performance of each operator was calculated. Criteria of adequacy were established by a review of the published findings and an analysis of the relation between trephine length and the rate of infiltration by tumour. RESULTS: Before processing, the average trephine was 1.59 cm long. Trephines shrunk by 25% during processing. In histological sections the average length was 1.15 cm, consisting of 0.09 cm of soft tissue, 0.04 cm of cortex, 0.26 cm of disrupted marrow and 0.74 cm of interpretable marrow. A large number of operators were taking trephine biopsy specimens and their performance varied considerably. Review of the published findings suggested that the minimum adequate length is in the range 1.5 cm to 2.0 cm. The analysis of the relation between length of trephine and the rate of positivity for neoplasia yielded a minimum adequate length of 1.2 cm in section (1.6 cm before processing). Fifty eight per cent of the trephines were inadequate by this criterion. There was a tendency for the Jamshidi needle to produce a longer trephine than the Islam needle. CONCLUSION: According to objective criteria, at the Christie Hospital, many operators are producing a high proportion of inadequate bone marrow trephines.

Full text

Full text is available as a scanned copy of the original print version. Get a printable copy (PDF file) of the complete article (764K), or click on a page image below to browse page by page. Links to PubMed are also available for Selected References.

Images in this article

Click on the image to see a larger version.

Selected References

These references are in PubMed. This may not be the complete list of references from this article.
  • Jamshidi K, Swaim WR. Bone marrow biopsy with unaltered architecture: a new biopsy device. J Lab Clin Med. 1971 Feb;77(2):335–342. [PubMed]
  • Brynes RK, McKenna RW, Sundberg RD. Bone marrow aspiration and trephine biopsy. An approach to a thorough study. Am J Clin Pathol. 1978 Nov;70(5):753–759. [PubMed]
  • Islam A. A new bone marrow biopsy needle with core securing device. J Clin Pathol. 1982 Mar;35(3):359–364. [PMC free article] [PubMed]
  • Brunning RD, Bloomfield CD, McKenna RW, Peterson LA. Bilateral trephine bone marrow biopsies in lymphoma and other neoplastic diseases. Ann Intern Med. 1975 Mar;82(3):365–366. [PubMed]

Articles from Journal of Clinical Pathology are provided here courtesy of BMJ Group

Formats:

Related citations in PubMed

See reviews...See all...

Cited by other articles in PMC

See all...

Links

  • PubMed
    PubMed
    PubMed citations for these articles

Recent Activity

Your browsing activity is empty.

Activity recording is turned off.

Turn recording back on

See more...