• We are sorry, but NCBI web applications do not support your browser and may not function properly. More information
Logo of nihpaAbout Author manuscriptsSubmit a manuscriptNIH Public Access; Author Manuscript; Accepted for publication in peer reviewed journal;
J Am Chem Soc. Author manuscript; available in PMC Aug 19, 2010.
Published in final edited form as:
PMCID: PMC2739123
NIHMSID: NIHMS135252

Carbon Dots for Optical Imaging in vivo

There has been significant recent interest in the development of highly fluorescent nanomaterials as contrast agents for optical imaging in vivo.1 The imaging agents should ideally be bright, nontoxic, biocompatible, and stable against photobleaching. Among the extensively studied are those based on semiconductor quantum dots (QDs) such as CdSe/ZnS.2 The rationale for the use of QDs over conventional organic dyes is now generally accepted in the literature.3 There are already successful in vivo imaging demonstrations of QDs on tumor vasculature, tumor-specific membrane antigens, sentinel lymph nodes, etc.2,4

The semiconductor QDs containing cadmium or other heavy metals are unfortunately known for their significant toxicity even at relatively low concentrations,5,6 which may prove prohibitive to any patient studies. Therefore, the search for benign alternatives has continued. Of particular interest and significance was the recent finding that small carbon nanoparticles could be surface-passivated by organic or bio-molecules to become strongly fluorescent.7 These fluorescent carbon nanoparticles,7,8 dubbed “carbon dots” (C-Dots, Scheme 1), were found to be physicochemically and photochemically stable and non-blinking. The carbon particle core could also be doped with an inorganic salt such as ZnS before the surface functionalization to significantly enhance the fluorescence brightness (CZnS-Dots, Scheme 1).9 These carbon dots have been successfully used for in vitro cell imaging with both one- and two-photon excitations.7,9,10

Carbon is hardly considered as an intrinsically toxic element. Available results from the ongoing toxicity evaluation of the oligomeric PEG-functionalized C-Dots7 in mice have suggested no meaningful toxic effects,11 raising the prospect for in vivo biocompatibility and uses of carbon dots. Here we report the first study of carbon dots for optical imaging in vivo. The results suggest that the carbon dots are not only brightly fluorescent in solution, as reported previously,7,9 but also well-behaved as contrast agents in live mice.

The C-Dots and CZnS-Dots with the PEG diamine, H2NCH2(CH2CH2O)nCH2CH2CH2NH2 (n ~ 35, PEG1500N), as the surface passivation agent were prepared and characterized as previously reported.7,9,10 Shown in Figure 1 are representative AFM and HR-TEM imaging results of the carbon dots. Both samples were readily soluble in water to form stable aqueous solutions, suitable for the various injections as follows.

Figure 1
AFM topography images of C-Dots (left) and CZns-Dots (right) on mica, with the insets showing the corresponding HR-TEM images of individual dots.

For subcutaneous injection, female DBA/1 mice (~25 g) were shaved in the back area surrounding the injection point. Upon the injection of a C-Dots solution (30 µg carbon core-equivalent in 30 µL) or a CZnS-Dots solution (65 µg in 30 µL), the mice were imagined in a Lumazone FA in vivo Imaging System (MAG Biosystems) with 470 nm (FWHM ~ 40 nm) excitation and 525 nm (FWHM ~ 47 nm) emission filters. As shown in Figure 2, the fluorescence images of the subcutaneously injected mice exhibited bright emissions from C-Dots and CZnS-Dots. The relatively stronger fluorescence from the latter is consistent with the previously reported solution-phase results.9 The injected carbon dots in mice diffused relatively slowly, with the fluorescence faded about 24 h post-injection.

Figure 2
Subcutaneous injection: (a) bright field, (b,d) as-detected fluorescence (excitation/emission wavelengths indicated), and (c,e) color-coded images (ImageJ from NIH).

The carbon dots could be excited at longer wavelengths for red fluorescence emissions. For the same subcutaneous injection into mice, the imaging results with 545 nm (FWHM ~ 29 nm) excitation and 620 nm (FWHM ~ 59 nm) emission filters also exhibited significant fluorescence from both C-Dots and CZnS-Dots (Figure 2).

The brighter green fluorescence of CZnS-Dots was used in the imaging to track the migration through lymph vessels. Upon interdermal injection into the front extremity (10 µg in 10 µL), the carbon dots could migrate along the arm (Figure 3). Unlike in semiconductor quantum dots such as CdSe/ZnS, which could migrate to axillary lymph nodes in minutes,4c the observed migration of the carbon dots was slower. This could be due to the small sizes of carbon dots (on the order of 4–5 nm) and/or the surface functionalization by the PEGs, whose protein resistance characteristics might reduce interactions of the carbon dots with lymph cells. The axillary lymph nodes were harvested and dissected at 24 h post-injection, in which fluorescence from the carbon dots could readily be detected (Figure 3).

Figure 3
Interdermal injection: (a) bright field, (b) as-detected fluorescence, and (c) color-coded images. Insets: the dissected (in the circled area) axillary lymph node (LN).

A C-Dots solution (440 µg in 200 µL) was intravenously injected into mice for whole body circulation. The abdomen was shaved for fluorescence detection of the dots trapped in organs during the circulation, but only emissions from the bladder area were observed (Figure 4). About 3 h post-injection, bright fluorescence in the urine became visible in the imaging facility (Figure 4). The results suggest primarily urine excretion for the intravenously injected carbon dots, which has been a widely observed excretion pathway in the literature for PEGylated nanoparticles, especially for very small particles like the ones used here.12

Figure 4
Intravenous injection: (a) bright field, (b) as-detected fluorescence (Bl: bladder and Ur: urine), and (c) color-coded images. The same order for the images of the dissected kidneys (lower left) and liver (lower right).

The organs were harvested 4 h post-intravenous injection for imaging analyses ex vivo. Only the dissected kidneys and liver exhibited meaningful fluorescence from the carbon dots, brighter in the former (Figure 4), consistent with the urine excretion pathway. The relatively weak fluorescence in the dissected liver was an indication for low accumulation level of the carbon dots. While generally significant hepatic uptake of nanoparticles and nanorubes was widely observed and discussed in many studies,13 the low accumulation here might again be attributed to the effective surface PEGylation that probably reduced the protein affinity and made the carbon dots stealth with respect to the hepatic uptake.

All of the reported animal experiments were performed at Clemson University by strictly following the IACUC approved protocols. During the experiments, no animal exhibited any sign of acute toxicological responses.

In summary, the results reported here demonstrate that carbon dots, injected into mice via various ways, remain strongly fluorescent in vivo, which coupled with their biocompatibility and nontoxic characteristics might offer great potentials in optical imaging and related biomedical applications.

Supplementary Material

1_si_001

Acknowledgment

We thank Hilary Hicks of MAG Biosystems for experimental assistance. This work was supported primarily by a Susan G. Komen for the Cure Postdoctoral Fellowship Award (L.C. and Y.-P.S.) and by NIH (Y.-P.S.). H.W. and Y.L. also acknowledge financial support from NSFC and China Ministry of Science and Technology.

Footnotes

Supporting Information Available: Complete ref 7 and more experimental details. This material is available free of charge via the Internet at http://pubs.acs.org.

References

1. De M, Ghosh PS, Rotello VM. Adv. Mater. 2008;20:4225–4241.
2. Michalet X, Pinaud FF, Bentolila LA, Tsay JM, Doose S, Li JJ, Sundaresan G, Wu AM, Gambhir SS, Weiss S. Science. 2005;307:538–544. [PMC free article] [PubMed]
3. (a) Alivisatos AP. Science. 1996;271:933–937. (b) Chan WCW, Nie S. Science. 1998;281:2016–2018. [PubMed]
4. (a) Smith BR, Cheng Z, De A, Koh AL, Sinclair R, Gambhir SS. Nano Lett. 2008;8:2599–2606. [PubMed] (b) Gao X, Cui Y, Levenson RM, Chung LWK, Nie S. Nat. Biotechnol. 2004;22:969–976. [PubMed] (c) Kim S, Lim YT, Soltesz EG, Grand AMD, Lee J, Nakayama A, Parker JA, Mihaljevic T, Laurence RG, Dor DM, Cohn LH, Bawendi MG, Frangioni JV. Nat. Biotechnol. 2004;22:93–97. [PubMed]
5. Hardman R. Environ. Health Perspect. 2006;114:165–172. [PMC free article] [PubMed]
6. Lin P, Chen J-W, Chang LW, Wu J-P, Redding L, Chang H, Yeh T-K, Yang CS, Tsai M-H, Wang H-J, Kuo Y-C, Yang RSH. Environ. Sci. Technol. 2008;42:6264–6270. [PubMed] (b) Geys J, Nemmar A, Verbeken E, Smolders E, Ratoi M, Hoylaerts MF, Nemery B, Hoet PHM. Environ. Health Perspect. 2008;116:1607–1613. [PubMed]
7. Sun Y-P, et al. J. Am. Chem. Soc. 2006;128:7756–7757. [PubMed]
8. (a) Liu H, Ye T, Mao C. Angew. Chem. Int. Ed. 2007;46:6473–6475. [PubMed] (b) Zhou J, Booker C, Li R, Zhou X, Sham T-K, Sun X, Ding Z. J. Am. Chem. Soc. 2007;129:744–745. [PubMed] (c) Zhao QL, Zhang ZL, Huang BH, Peng J, Zhang M, Pang DW. Chem. Comm. 2008:5116–5118. [PubMed] (d) Bourlinos AB, Stassinopoulos A, Anglos D, Zboril R, Karakassides M, Giannelis EP. Small. 2008;4:455–458. [PubMed] (e) Hu S-L, Niu K-Y, Sun J, Yang J, Zhao N-Q, Du X-W. J. Mater. Chem. 2009;19:484–488.
9. Sun Y-P, Wang X, Lu F, Cao L, Meziani MJ, Luo PG, Gu L, Veca LM. J. Phys. Chem. C. 2008;112:18295–18298. [PMC free article] [PubMed]
10. Cao L, Wang X, Meziani MJ, Lu F, Wang H, Luo PG, Lin Y, Harruff BA, Veca LM, Murray D, Xie S-Y, Sun Y-P. J. Am. Chem. Soc. 2007;129:11318–11319. [PMC free article] [PubMed]
11. Yang S-T, Wang X, Wang H, Lu F, Luo PG, Cao L, Liu J-H, Liu Y, Chen M, Huang Y, Sun Y-P. unpublished results.
12. Choi HS, Liu W, Misra P, Tanaka E, Zimmer JP, Ipe BI, Bawendi MG, Frangioni JV. Nat. Biotechnol. 2007;25:1165–1170. [PMC free article] [PubMed]
13. Li S-D, Huang L. Mol. Pharmaceutics. 2008;5:496–504. [PubMed]
PubReader format: click here to try

Formats:

Related citations in PubMed

See reviews...See all...

Cited by other articles in PMC

See all...

Links

  • PubMed
    PubMed
    PubMed citations for these articles
  • Substance
    Substance
    PubChem Substance links

Recent Activity

Your browsing activity is empty.

Activity recording is turned off.

Turn recording back on

See more...