![]() | ![]() |
Formats:
|
||||||||||||
Copyright © 2009 Quaranta et al; licensee BioMed Central Ltd. Nest expansion assay: a cancer systems biology approach to in vitro invasion measurements 1Integrated Mathematical Oncology, Moffitt Cancer Center, Tampa, FL, USA 2School of Community Health, Charles Sturt University, Albury, Australia 3Department of Cancer Biology, Vanderbilt University School of Medicine, Nashville, TN, USA Corresponding author.Yoonseok Kam: yoonseok.kam/at/moffitt.org; Audrey Karperien: akarperien/at/yahoo.com; Brandy Weidow: brandy.weidow/at/vanderbilt.edu; Lourdes Estrada: lourdes.estrada/at/vanderbilt.edu; Alexander R Anderson: alexander.anderson/at/moffitt.org; Vito Quaranta: vito.quaranta/at/vanderbilt.edu Received May 13, 2009; Accepted July 13, 2009. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. Abstract Background Traditional in vitro cell invasion assays focus on measuring one cell parameter at a time and are often less than ideal in terms of reproducibility and quantification. Further, many techniques are not suitable for quantifying the advancing margin of collectively migrating cells, arguably the most important area of activity during tumor invasion. We have developed and applied a highly quantitative, standardized, reproducible Nest Expansion Assay (NEA) to measure cancer cell invasion in vitro, which builds upon established wound-healing techniques. This assay involves creating uniform circular "nests" of cells within a monolayer of cells using a stabilized, silicone-tipped drill press, and quantifying the margin expansion into an overlaid extracellular matrix (ECM)-like component using computer-assisted applications. Findings The NEA was applied to two human-derived breast cell lines, MCF10A and MCF10A-CA1d, which exhibit opposite degrees of tumorigenicity and invasion in vivo. Assays were performed to incorporate various microenvironmental conditions, in order to test their influence on cell behavior and measures. Two types of computer-driven image analysis were performed using Java's freely available ImageJ software and its FracLac plugin to capture nest expansion and fractal dimension, respectively – which are both taken as indicators of invasiveness. Both analyses confirmed that the NEA is highly reproducible, and that the ECM component is key in defining invasive cell behavior. Interestingly, both analyses also detected significant differences between non-invasive and invasive cell lines, across various microenvironments, and over time. Conclusion The spatial nature of the NEA makes its outcome susceptible to the global influence of many cellular parameters at once (e.g., motility, protease secretion, cell-cell adhesion). We propose the NEA as a mid-throughput technique for screening and simultaneous examination of factors contributing to cancer cell invasion, particularly suitable for parameterizing and validating Cancer Systems Biology approaches such as mathematical modeling. Background Classical wound-healing, cell migration, and cancer invasion assays have been carried out in tissue culture for decades, primarily to generate information about the relationship between cell motility and invasion [1-3]. However, a number of these techniques are encumbered with problems of quantification, reproducibility, and flexibility. For example, traditional wound-healing, or "scratch" assays include creation of an artificial wound (i.e., a scratch) within a monolayer of cells using a blunt object (e.g., pipet tip), and subsequent quantification of cells repopulating the scratch over time [1]. Not surprisingly, such assays often produce crude quantitative data, since they are typically difficult to standardize and reproduce [4-6]. A number of modified assays have been designed to overcome this problem, such as microfabrication printing [7], electrical impedance [4], and semi-automated press techniques [8], but have not reached widespread application. Another traditional cell migration assay, the Boyden chamber technique as variously modified [2], is widely used but its major limitations are that single cells cannot be visualized and collective cell migration is not testable. That is, these assays capture only the average behavior of a cell population, which can mask underlying dynamics and other valuable information about cell interactions (e.g., cell line heterogeneity, cell-ECM interface). Perhaps for these reasons, this technique has often yielded data inconsistent with in vivo findings [4,5]. Cell invasion assays based on three-dimensional (3-D) microscopy [9] provide excellent data collection at the single cell level, and track collective migration, but typically require several days or weeks of incubation for formation of colonies and use advanced microscopy methods for analysis, making them unsuitable for mid- and high- throughput studies. Further, migration assays designed for microplate readers or confocal microscopy typically require labeling of cells (e.g., using fluorescent probes) either prior to or after incubation – often an undesirable parameter [10]. In summary, many of the discussed techniques supply information about the average motility of a cell population, but fail to provide sufficient resolution for yielding precise information about individual cells or their spatial arrangement. Other techniques provide information on single cells and their arrangement, but are low-throughput. Together, the aforementioned techniques have provided important focused insights into cell motility mechanisms, as they are generally limited to measuring one parameter at a time [4,5], and their output is still adequate for many uses. However, we submit that there is an increasing need for a standardized, flexible, objective invasion assay with high-resolution for inspection of individual cells that can provide quantitative spatial information in a timely manner. This need is made more acute by the rise, in recent years, of theoretical Cancer Systems Biology approaches, in order to better incorporate the complex, multi-factorial interplay of tumor cells with their microenvironment [9]. The NEA builds upon our previous Circular Invasion Assay (CIA; [11]). We now include, as a standard procedure, a Matrigel overlay, which is representative of tumor growth into surrounding tissues in vivo [12]. Several in vitro invasion studies have shown that inclusion of this component leads cells to exhibit closer behavior to that seen in vivo [3]. However, the key improvement is that a silicone-tipped drill press is used to create circular nests of cancer cells within an intact monolayer. Expansion of these nests is then recorded by high content microscopy (Figure (Figure1).1
We also focused our efforts on efficiently and objectively quantifying the NEA experimental output. Straightforward "nest expansion" measurements (based on area) were systematically captured by computer-aided analysis of phase-contrast, time-lapse microscopy images using Java's freely available ImageJ software [14]. However, some irregular patterns, such as contours of biological cells or tumor colonies, are more difficult to describe using simple Euclidean measures (e.g., diameter, length); these objects can instead be quantitatively assessed using measures of complexity [15]. One such measurement that captures the irregularity of contours, or the borders of invasive nests in our case, is called the fractal dimension (Df) [16]. Fractal analysis is a tool sometimes employed in the fields of pathology and radiology to measure the irregularities associated with cancer growth and prognosis. In the past, it has been applied as a tool for assessing melanoma lesions in situ [17], glioblastoma invasion captured by MMR scanning [18], activated lymphocytes in vitro [19], and various cancer masses extracted from both laboratory animals and human patients [16,20,21]. Fractal interfaces between tumor and non-tumor regions (i.e., ECM) show temporal and spatial variances during the process of "roughening", or the increase of irregularity of a growth front, and can be used as an indicator of whether the tumor is likely to become infiltrative or not [16]. Ultimately, the real value of this measurement is that it provides an objective, quantitative approach for classifying organization and/or disorganization, something that is difficult for pathologists to do by eye [16]. To our advantage, some available software, such as ImageJ's Fractal Dimension and Lacunarity plugin (FracLac; [22]), can assess images for this measurement with some user interaction and troubleshooting (and is freely available online). We therefore employed this quantitative technique to assess the advancing borders of nests in the NEA. The NEA was designed with Cancer Systems Biology in mind, in that the spatial nature of its setup makes its outcome more susceptible to the simultaneous influence of many cellular parameters (e.g., motility, protease secretion, cell-cell adhesion, cell-matrix adhesion). These techniques are necessary for directly probing the complex interactions between cells and the microenvironment, particularly at the single-cell level, in order to reconstruct, e.g, with the aid of mathematics and computation, networks and mechanisms associated with cancer. Availability and requirements Cell Culture MCF10A (and MCF10A-GFP), a human cell line derived from spontaneous immortalization of breast epithelial cells that is non-tumorigenic in nude mice [23], and MCF10A-CA1d (CA1d), a cell line derived from xenograph-passaging in nude mice creating a more aggressive, metastatic cell line [24], were maintained in constant culture. For a detailed description of method, see Additional File 1. Both cell lines are readily available through the Vanderbilt Integrative Cancer Biology Center's (VICBC) Tissue Culture Core Unit http://www.vanderbilt.edu/VICBC. Nest Expansion Assay (NEA) Slightly altering our previously developed circular invasion assay (CIA; [11]), uniform, circular, artificial wounds were generated using a stabilized, rotating, silicone-tipped drill-press (Delta Shopmaster, Type 1, Model DP200). For the NEA, we purposely tilted the sterilized silicone tip to leave a circular nest of cells (8 per dish; ~800 μm in diameter) within each wounded area in order to examine outward cell invasion into overlaid Matrigel (Figure (Figure1).1 Live Cell Imaging Time-lapse microscopy was conducted using a Zeiss Axiovert 200 M microscope (Zeiss, Thornwood, NY; 2.5× Plan NEOFLUR objective, NA 0.075; 10× Achroplan, NA 0.25, Ph1 objective) equipped with a Hamamatsu ORCA-ER CCD camera and temperature- and CO2-controlled chamber. Microscopy was under the control of OpenLab software (Improvision, Lexington, MA). At the beginning of each experiment (0 h), phase-contrast images of "wounded" monolayers were microscopically examined for standard reproducible cuts, images of each captured, and irregular outliers were discarded from the data set (negligible; data not shown). Nests expanding into the wounded areas were subsequently imaged at regular time points for up to 36 h. Image Processing and Nest Expansion Quantification Fractal Image Analysis Statistical Analysis Statistical analyses were performed using SPSS, version 16 (SPSS Inc., Chicago, IL). Each cell line was sampled at least 8 times (N ≥ 8), for each treatment. To avoid confounding problems with multiple analyses along the time-response curve, final differences were only analyzed at 0, 10, 22, 28 and 36 h (as indicated). Differences between cell lines and treatments were examined using Student's t-tests (2-sided), and were considered significant when P < 0.05. Results and discussion NEA captures cell line invasiveness in vitro The well-characterized cell lines, MCF10A and CA1d, have opposite degrees of invasiveness in vivo (non-aggressive, non-invasive, non-tumorigenic phenotype versus highly invasive, tumorigenic phenotype, respectively; [23,24]). To determine whether the NEA could produce results compatible with these in vivo findings, we first applied it to these cells both in the presence and absence of Matrigel for comparison. Multiple applications of a tilted, rotating silicone-tipped drill press on a confluent monolayer of cells in a Petri dish left behind uniform nests of cells (Figure (Figure1).1
ImageJ analysis revealed that, in the absence of Matrigel, MCF10A nests expanded somewhat more than CA1d nests after 10 h (Figure (Figure2A;2A Fractal analysis distinguishes noninvasive from invasive fronts In the NEA, the invasive front of nests into the overlaid Matrigel barrier is examined by direct microscopic visualization. Obtaining quantitative spatial measurements at this cell-ECM interaction site, arguably the most important area of activity during tumor invasion [25], has proven to be a difficult feat by most classical methods [15]. However, fractal analysis has emerged as one approach to measuring the irregularity, or "complexity", of cell or colony borders. This tool can be an efficient and objective means for describing these complex shapes, otherwise subject to person-to-person variance. Java's ImageJ FracLac plugin assesses images for the Df measurement, providing that the user supplies the program with adequately processed images to isolate the ROI. We used this plugin to obtain Df measures for the nest contours, which outline the leading edge of expansion. We first explored and validated FracLac by analyzing two classical, simulated test patterns of known Df, a perfect two-dimensional (2-D) circle [26] and the "Koch snowflake" ([27]; Figure Figure3).3
NEA and fractal analysis capture invasive differences linked to microenvironmental conditions A few previous studies have reported invasive "fingering" patterns at the edge of certain types of tumors both in vitro and in vivo, which depend on microenvironmental conditions [28,29]. A few mathematical and computational modeling approaches have also demonstrated this microenvironment-dependent pattern in in silico tumors [30]. One such model, the Hybrid Discrete-Continuum (HDC) mathematical model presented in Anderson et al. [30], reported an association between stressful conditions and invasive front complexity. In the HDC model, a 2-D lattice represents the tissue domain where cells reside, including ECM and other factors [30]. Using this approach, the model can predict various patterns of invasion dependent upon cells' interactions with their microenvironment (as represented by various parameters in model). To test ideas generated by HDC in silico results, we slightly modified the initial NEA method to examine co-cultured, fluorescently labeled cells under two different microenvironmental conditions. Specifically, MCF10A cells were GFP-labeled prior to seeding (MCF10A-GFP), and final nests were fixed and stained with rhodamine-phalloidin to mark actin filaments, in order to visualize unlabeled cells (CA1d) prior to fluorescence imaging. End-point assays were performed with MCF10A-GFP or CA1d alone, or with MCF10A-GFP mixed with either unlabeled MCF10A (1:1) or CA1d (1:1). All nests were overlaid with a single, 50% Matrigel density, to model space constraints. Nests were allowed to expand in the presence or absence of serum for either 36 or 28 h, respectively. The shorter incubation period was required for serum-free conditions, because cell death became an issue with longer times. Microscopic images were then processed and assessed for both nest expansion and Df measures. Note that cells on the other side of outer "wound" rings were excluded from analysis. Figure Figure4A4A
In magnified images (10×; Figure Figure4C),4C One of the major predictions of the HDC model is that under stressful conditions of growth and space constraints, more aggressive phenotypes become dominant [30]. The experimental observation that MCF10A cells were trapped by the aggressive CA1d cells in the mixed nests of the NEA agrees with that prediction. Furthermore, the HDC model predicted more complex margins in colonies of aggressive cells, under stressful conditions [30]. The NEA finding also agrees with this prediction. Clearly, these initial correlations show that there is merit to the NEA, but additional in-depth studies are needed to solidify these tentative conclusions. In summary, the benefits of the NEA approach are many. For instance, because we use a machine-based approach (drill press to create wounds, and computer-assisted analyses for measurements), the assay setup is not subject to operator variance, and is both highly reproducible and objective. Nonetheless, the NEA setup is flexible to introduction of various perturbations (e.g., additional and diverse microenvironmental stressors). Since nests can be assessed for area and Df simultaneously, a more detailed quantitative picture of cells' invasive potential is achieved with a single assay. Lastly, because NEA relies on high-content microscopy imaging, cells are examined both at the population and the single-cell level, making it particularly useful for individual-based mathematical/computational modeling. We are hopeful that this tool will help bridge the gap between in silico outcomes and in vivo validation. Abbreviations used 2-D: two-dimensional; 3-D: three-dimensional; CIA: Circular Invasion Assay; Df: fractal dimension; ECM: extracellular matrix; HDC: Hybrid-Discrete Continuum; NEA: Nest Expansion Assay; ROI: region of interest. Competing interests The authors declare that they have no competing interests. Authors' contributions YK performed all NEA experiments, contributed intellectual property, and contributed to manuscript preparation; AK performed fractal analyses and contributed to manuscript preparation; BW performed data analysis, statistical testing, and contributed to manuscript preparation; LE contributed to manuscript preparation; ARA contributed to manuscript preparation; VQ conceived of this study and contributed to manuscript preparation. Acknowledgements This work was supported by NIH grant U54CA113007-04 awarded to VQ. References
|
PubMed related articles
Your browsing activity is empty. Activity recording is turned off. |
|||||||||||
Proc Natl Acad Sci U S A. 2004 Feb 10; 101(6):1554-9.
[Proc Natl Acad Sci U S A. 2004]J Clin Gastroenterol. 1995; 21 Suppl 1():S40-4.
[J Clin Gastroenterol. 1995]Science. 2001 Nov 23; 294(5547):1708-12.
[Science. 2001]Methods Mol Biol. 2000; 139():321-43.
[Methods Mol Biol. 2000]BMC Cancer. 2008 Jul 14; 8():198.
[BMC Cancer. 2008]Cancer Chemother Rep. 1970 Jun; 54(3):143-74.
[Cancer Chemother Rep. 1970]J Biomed Eng. 1992 May; 14(3):229-34.
[J Biomed Eng. 1992]Med Biol Eng Comput. 2005 Jul; 43(4):436-42.
[Med Biol Eng Comput. 2005]Pathol Res Pract. 1992 Jun; 188(4-5):680-6.
[Pathol Res Pract. 1992]J Anat. 2007 Nov; 211(5):673-80.
[J Anat. 2007]J Cereb Blood Flow Metab. 2007 Feb; 27(2):293-303.
[J Cereb Blood Flow Metab. 2007]J Natl Cancer Inst. 1993 Nov 3; 85(21):1725-32.
[J Natl Cancer Inst. 1993]Breast Cancer Res Treat. 2001 Jan; 65(2):101-10.
[Breast Cancer Res Treat. 2001]BMC Cancer. 2008 Jul 14; 8():198.
[BMC Cancer. 2008]J Natl Cancer Inst. 1993 Nov 3; 85(21):1725-32.
[J Natl Cancer Inst. 1993]Breast Cancer Res Treat. 2001 Jan; 65(2):101-10.
[Breast Cancer Res Treat. 2001]Nature. 2006 May 25; 441(7092):444-50.
[Nature. 2006]Vet Clin Pathol. 2006 Dec; 35(4):446-8.
[Vet Clin Pathol. 2006]Ann Surg Innov Res. 2008 Apr 2; 2():1.
[Ann Surg Innov Res. 2008]Cell Prolif. 2001 Apr; 34(2):115-34.
[Cell Prolif. 2001]Cell. 2006 Dec 1; 127(5):905-15.
[Cell. 2006]Cell. 2006 Dec 1; 127(5):905-15.
[Cell. 2006]