Abstract

Blood cultures collected in BACTEC Plus Aerobic/F bottles and BACTEC Plus Anaerobic/F bottles were monitored for 5 days by BACTEC 9240 and subsequent terminal subcultures. Of the 13,471 bottles subcultured, 11.0% (1,477 of 13,471) were culture positive. Of these, 94.0% (1,388 of 1,477) were detected by BACTEC 9240; the additional 6.0% (89 of 1,477) were considered to be false negatives by BACTEC 9240 since they were detected by terminal subculture only. The false-negative bottles consisted of 17 BACTEC Plus Aerobic/F and 72 BACTEC Plus Anaerobic/F bottles, accounting for 2.2 (17 of 786) and 10.4% (72 of 691) of the total positive aerobic and anaerobic bottles, respectively. The positive blood culture bottles most frequently not detected by BACTEC 9240 grew Pseudomonas spp. (24), Staphylococcus spp. (21), and yeasts (24). Of the 86 blood cultures represented by the 89 false-negative bottles, 41 would not have been identified as positive since the other bottle in the blood culture set was either a false negative or a true negative. In general, terminal subcultures of false-negative BACTEC bottles had heavy growth, indicating that BACTEC Plus media were able to support the growth of microorganisms, but the BACTEC 9240 instrument was unable to detect this growth.

Full Text

The Full Text of this article is available as a PDF (208K).

Selected References

These references are in PubMed. This may not be the complete list of references from this article.
  • Appelbaum PC, Beckwith DG, Dipersio JR, Dyke JW, Salventi JF, Stone LL. Enhanced detection of bacteremia with a new BACTEC resin blood culture medium. J Clin Microbiol. 1983 Jan;17(1):48–51. [PMC free article] [PubMed]
  • Ilstrup DM. Statistical methods in microbiology. Clin Microbiol Rev. 1990 Jul;3(3):219–226. [PMC free article] [PubMed]
  • Koontz FP, Flint KK, Reynolds JK, Allen SD. Multicenter comparison of the high volume (10 ml) NR BACTEC PLUS system and the standard (5 ml) NR BACTEC system. Diagn Microbiol Infect Dis. 1991 Mar-Apr;14(2):111–118. [PubMed]
  • Murray PR, Traynor P, Hopson D. Critical assessment of blood culture techniques: analysis of recovery of obligate and facultative anaerobes, strict aerobic bacteria, and fungi in aerobic and anaerobic blood culture bottles. J Clin Microbiol. 1992 Jun;30(6):1462–1468. [PMC free article] [PubMed]
  • Nolte FS, Williams JM, Jerris RC, Morello JA, Leitch CD, Matushek S, Schwabe LD, Dorigan F, Kocka FE. Multicenter clinical evaluation of a continuous monitoring blood culture system using fluorescent-sensor technology (BACTEC 9240). J Clin Microbiol. 1993 Mar;31(3):552–557. [PMC free article] [PubMed]
  • Tarrand JJ, Guillot C, Wenglar M, Jackson J, Lajeunesse JD, Rolston KV. Clinical comparison of the resin-containing BACTEC 26 Plus and the Isolator 10 blood culturing systems. J Clin Microbiol. 1991 Oct;29(10):2245–2249. [PMC free article] [PubMed]
  • Weinstein MP, Mirrett S, Wilson ML, Harrell LJ, Stratton CW, Reller LB. Controlled evaluation of BACTEC Plus 26 and Roche Septi-Chek aerobic blood culture bottles. J Clin Microbiol. 1991 May;29(5):879–882. [PMC free article] [PubMed]
  • Wilson ML, Harrell LJ, Mirrett S, Weinstein MP, Stratton CW, Reller LB. Controlled evaluation of BACTEC PLUS 27 and Roche Septi-Chek anaerobic blood culture bottles. J Clin Microbiol. 1992 Jan;30(1):63–66. [PMC free article] [PubMed]

Articles from Journal of Clinical Microbiology are provided here courtesy of American Society for Microbiology (ASM)

Formats:

Related citations in PubMed

See reviews...See all...

Cited by other articles in PMC

See all...

Links

Recent Activity

Your browsing activity is empty.

Activity recording is turned off.

Turn recording back on

See more...