![]() | ![]() |
Formats:
|
||||||||||||||||||||||||||||
Copyright © 2007 The Author(s). Novel DNA probes with low background and high hybridization-triggered fluorescence Nanogen, Inc., 21720 23rd Drive SE, Suite 150, Bothell, WA 98021, USA *To whom correspondence should be addressed. Phone: +1 425 482 5168, Fax: +1 425 482 5550, Email: elukhtanov/at/nanogen.com Present address: Sergey G. Lokhov, Cepheid, 1631 220th Street SE, Suite 101, Bothell, WA 98021, USA; Mikhail A. Podyminogin, Integrated DNA Technologies, Inc., 1710 Commercial Park, Coralville, IA 52241, USA The authors wish it to be known that, in their opinion, the first two authors should be regarded as joint First Authors. Received October 13, 2006; Revised December 8, 2006; Accepted December 13, 2006. This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/2.0/uk/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. Abstract Novel fluorogenic DNA probes are described. The probes (called Pleiades) have a minor groove binder (MGB) and a fluorophore at the 5′-end and a non-fluorescent quencher at the 3′-end of the DNA sequence. This configuration provides surprisingly low background and high hybridization-triggered fluorescence. Here, we comparatively study the performance of such probes, MGB-Eclipse probes, and molecular beacons. Unlike the other two probe formats, the Pleiades probes have low, temperature-independent background fluorescence and excellent signal-to-background ratios. The probes possess good mismatch discrimination ability and high rates of hybridization. Based on the analysis of fluorescence and absorption spectra we propose a mechanism of action for the Pleiades probes. First, hydrophobic interactions between the quencher and the MGB bring the ends of the probe and, therefore, the fluorophore and the quencher in close proximity. Second, the MGB interacts with the fluorophore and independent of the quencher is able to provide a modest (2–4-fold) quenching effect. Joint action of the MGB and the quencher is the basis for the unique quenching mechanism. The fluorescence is efficiently restored upon binding of the probe to target sequence due to a disruption in the MGB–quencher interaction and concealment of the MGB moiety inside the minor groove. INTRODUCTION Fluorogenic hybridization probes are probes whose fluorescence signal changes upon hybridization with a target sequence. Several types of such probes have been described. They can generally be divided into two groups: dual-labeled and single-labeled probes. The first group of probes utilizes an alteration of dye–dye interactions resulting from hybridization to target sequence to generate a change in fluorescence intensity. Molecular beacons (1) belong to this group. These probes are stem-loop structures with the sequence recognition region located in the loop and the stem serving to bring fluorescent dye and non-fluorescent quencher in close proximity. It has been shown that so-called contact quenching is responsible for the efficient quenching effect (2). Upon hybridization with a target sequence, the dyes are spatially separated which results in a significant fluorescence increase. A similar design is used in the so-called scorpion PCR primers (3). Peptide nucleic acid (PNA) versions of molecular beacons have been developed (4,5). Several stemless dual-labeled probe formats (also called linear probes) have been described. The simplest linear probe contains two dyes at the opposite ends of an oligonucleotide sequence. One of the dyes is fluorescent, while the second one can be fluorescent (6) or non-fluorescent (7,8). The transition from single-stranded, randomly coiled probe to double-stranded DNA duplex is accompanied by a measurable change in fluorescence due to a median increase in distance between the dyes. A decrease in efficiency of fluorescence resonance energy transfer (FRET) from the donor to the acceptor dye is the major mechanism of signal generation for this type of probe (6). PNA versions (9,10) of linear probes demonstrate improved signal-to-background ratios compared to their DNA analogs (8). Since the quenching effect does not significantly depend on the distance between the dyes and their spectral overlap, it has been suggested that direct contact is the primary mode of energy transfer for this type of probe (9). Another way to improve quenching in DNA-based dual-labeled probes without using stem structures is described by Johansson et al. (11). It relies on intramolecular heterodimer formation between Cy3.5 or fluorescein and a non-fluorescent quencher called Black Hole Quencher. Dual-labeled hybridization probes with fluorophores and various intercalators have also been used (12–15). The fluorescence in these probes is quenched by the intercalator in the absence of a target sequence and becomes unquenched on hybridization with a target sequence due to the hindrance in quenching by intercalation. The second group of hybridization probes, single-labeled probes, relies on alteration of fluorescence efficiency of a single dye that takes place due to a hybridization event. Oxazole yellow-oligonucleotide (16) or thiazole orange-PNA (17) conjugates (light-up probes) have been described. These probes utilize the ability of the dyes to enhance fluorescence upon intercalation into double-stranded DNA. An improved version of the light-up probes exploits a thiazole orange-base in place of a regular PNA base to increase probe performance (18). The hybeacon probes (19) are also single-labeled oligonucleotides that increase their fluorescence upon hybridization. The increase is due to a disruption of quenching interactions in the single-stranded probe between fluorophore and nucleobases. The inherent quenching ability by deoxiguanosine nucleotides has been used to develop several single-labeled probe formats (20–22). Our focus in the DNA probe development has been on the exploration of minor groove binder (1,2-dihydro-3H-pyrrolo[3, 2-e]indole-7-carboxylate tripeptide) oligonucleotides and their application in genetic analysis. DNA probes with conjugated MGB groups form extremely stable duplexes with complementary single-stranded DNA targets, allowing shorter probes to be used for hybridization assay. This property provides improved mismatch discrimination (23) and allows more efficient probe synthesis. Two types of fluorogenic MGB probes have been previously reported. The first type, MGB-TaqMan (23,24) has the MGB ligand and a quencher located at the 3′-end of the probe while the fluorophore is attached at the 5′-end. This configuration allows the fluorophore to be cleaved and unquenched during PCR using the 5′->3′ nucleolytic activity of Taq DNA polymerase (25,26). The second type, the MGB-Eclipse™ (27,28), has the MGB and quencher located at the 5′-end and the fluorophore at the 3′-end. The 5′-positioning of the MGB protects the MGB-Eclipse probe from being cleaved during PCR and makes the probe available for post-PCR melting curve analysis (27,28). The fluorescence increase is generated by a transition of the probe from a randomly coiled to linearized state upon hybridization to target DNA. It has been observed that the MGB-probes have reduced fluorescence background compared to non-MGB analogs (23). This was attributed to a reduced length of the MGB probes and, therefore, relative proximity of the fluorophore and the quencher. Both MGB-TaqMan and MGB-Eclipse probe formats have fluorophore and the MGB attached at opposite ends of the DNA probe. We have recently discovered that when a fluorescent dye is positioned in close proximity to the MGB moiety, its fluorescence is substantially reduced. This surprising finding prompted us to investigate a novel design of hybridization probes, which we have called Pleiades probes (after one of the brightest star constellations in the night sky), wherein the fluorophore is located directly adjacent to the MGB at one of the ends of the probe, whereas the quencher is attached at the opposite end. We have found that this design provides extremely low background fluorescence. Moreover, when such probes are hybridized to complementary targets the fluorescence is efficiently released. The aim of the current study was to investigate fluorescence and hybridization properties of the novel probes and determine structural elements underlying the efficient fluorescence quenching for free probes and strong hybridization-triggered fluorescence. MATERIALS AND METHODS Synthesis of oligonucleotide probes 5′-DNA phosphoramidites (Pierce) were used for the preparation of Pleiades and Eclipse probes. Pleiades probes were synthesized on a MGB-modified DNA synthesis support (29) by first incorporating a fluorophore (LL-FAM, SL-FAM or YY, see Figure 1 M Tris-HCl pH 8.5 at ambient temperature and probes were assumed to have a random coil DNA structure in solution. For each MGB–Quencher, Eclipse Quencher, LL-FAM, SL-FAM and YY substitution a ε260 correction of +53 500, +6600, +33 300, +10 000 and +28 600 M−1cm−1 was used, respectively.
UV-vis and fluorescence studies UV-vis experiments were done on Perkin Elmer PE lambda2S or Varian Cary 400Bio UV-visible spectrophotometers. All fluorescence studies were done on a Varian Cary Eclipse fluorescence spectrometer equipped with a temperature-controlled cell holder. The buffer contained 40 mM NaCl, 10 mM Tris-HCl pH 8.9 and 5 mM MgCl2. Fluorescence was measured at 518 nm for FAM-labeled probes and 550 nm for YY-labeled probes with excitation at 496 and 530 nm, respectively.Fluorescence signals for single-stranded (0.1 or 0.2 μM) or hybridized probes (in the presence of 0.2 or 0.4 μM complement) were measured at 20°C. To assure equilibrium conditions were reached, duplex mixtures were heated at 60°C for 3 min and cooled to 20°C for measurement.Fluorescence versus temperature profiles for single-stranded probes and duplexes were obtained by increasing the temperature from 20 to 90°C at the ramp rate of 0.5°C/min. Probe concentration was 200 nM. For the sensitivity study (Figure 4 nM.
Fast hybridization kinetics of Pleiades probes and molecular beacons were studied with a rapid kinetics spectrophotometer accessory (Applied Photophysics, Surrey, UK) over a temperature range of 30–55°C. Probe and complement concentrations were 100 and 200 nM, respectively.RESULTS Background and hybridization fluorescence of Pleiades, MGB-Eclipse and molecular beacon probes Four sets of Pleiades (PL), MGB-Eclipse (EC) and molecular beacon (MB) probes were prepared (Table 1) to compare fluorescence properties of the three probe formats. Each set had a common core sequence and approximately equal duplex stabilities (Table 2). PL1 and PL2 sequences were shifted two bases downstream relatively to EC1 and EC2 sequences to avoid quenching by guanosine in the complementary strand (quenching data not shown). The molecular beacons had additional 5′-CGGC and GCCG-3′ stem-forming sequences (underlined in Table 1).
Fluorescence signals for probes before and after hybridization with complementary targets are summarized in Table 2. FAM-labeled Pleiades probes (PL1, PL1R) and molecular beacons (MB1, MB1R) show very low background fluorescence and high hybridization signal with signal-to-background (S/B) ratios of approximately 80–100 for Pleiades and 78–130 for molecular beacons. Hybridization signals for corresponding MGB-Eclipse (EC1, EC1R) are approximately equal to those of Pleiades. However, their high background fluorescences (6–10 times higher than that of Pleiades or molecular beacons) result in relatively low S/B ratios of only about 8–16. YY-labeled Pleiades (PL2 and PL2R) have extremely low background fluorescence and high S/B ratios (193 and 347 respectively). The ratio is 2–3 times higher than for the corresponding FAM analogs (PL1 and PL1R). Interestingly, the molecular beacon analogs (MB2, MB2R) are quenched about 3 times less efficiently even though they have the fluorophore and quencher conveniently brought together by the stem structure. YY-labeled MGB-Eclipse probes (EC2, EC2R) demonstrate even higher background fluorescence and relatively low S/B ratios (19 and 15, respectively). Temperature dependence of background fluorescence Stable temperature-independent fluorescence background is important for accuracy and sensitivity of post-PCR melting curve analysis. Therefore, we studied the temperature dependence of background fluorescence for molecular beacon, Pleiades and MGB-Eclipse probes (Figure 3
Hybridization specificity In order to compare the specificity of the probes, melting temperatures were determined for duplexes with fully matched and a single nucleotide mismatch sequences. Probes PL1, EC1 and MB1 were hybridized with C1 template (Table 1) to form fully matched duplex or with C2 template to form a G/G mismatch. Correspondingly, probes PL2, EC2 and MB2 were hybridized with C2 template to form fully matched duplex or with C1 template to form a C/C mismatch. First derivative melting curve analysis of these duplexes (Figure 2
Sensitivity Melting curve assay can be used to compare sensitivity limits for different probes. An example of such an assay is shown in Figure 4 nM concentrations were annealed with reducing amounts of complementary target followed by fluorescence melting curve analysis. The Pleiades probe showed clear specific melting transition down to 0.16 nM concentration; whereas the corresponding MGB-Eclipse analog started to show anomalous melting at 1 nM concentration. Therefore, under the conditions of the experiment the sensitivity limits for Pleiades and MGB-Eclipse were 0.16 and 4 nM correspondingly. Similar, unpredictable melting curves were observed at subnanomolar concentrations of the targets for the EC1 and EC2R MGB-Eclipse probes.Hybridization kinetics Figure 5
Investigation of quenching mechanism The absence of melting transitions (Figure 3 ~ 6–10). However, the cooperative effect of the MGB and the quencher (S/B ~ 45–75) is much greater than expected from the individual contributions.
All data presented in Table 4A were obtained with probes containing a relatively long hexaethylene glycol linker (Figure 1 As a next step we investigated absorption spectra of the Pleiades probes before and after addition of a complement. We used the PL3 probe as a typical example to illustrate the results of this study. The absorption spectrum of unhybridized probe clearly differs from the spectrum of a duplex with a complement (Figure 6 nm: MGB (which absorbs around 340 nm) by 2 nm; fluorescein (which absorbs around 495 nm) by 6 nm and quencher (which absorbs around 550 nm) by 23 nm. In addition to the shift, the absorbance intensity is increased for fluorescein and decreased slightly for the MGB. These changes in absorption spectra are indicative of possible interaction between the components of the probe. However, some of the changes could be due to differences in interactions of the dyes and MGB with DNA in single- and double-stranded states. To distinguish between these two situations we investigated spectra of simplified analogs of the PL3 probe in which one or two components were absent.
The results for single-labeled analogs are shown in Figure 6 nm red shift upon duplex formation and a slight drop in absorbance at 320 nm. This change can be attributed to the MGB binding to the minor groove. An 8 nm blue shift is observed for the quencher-only-labeled analog (Figure 6Figure 6 nm for free probe (compared to 534 nm for the Quencher-only analog (Figure 6 nm to 525 nm when complementary sequence is added. The MGB absorbance maximum in the free probe (346 nm) also differs from the one observed in the MGB-only analog (341 nm). This result clearly points to a prominent interaction between the MGB and the quencher in the unhybridized probe. Duplex formation disrupts this interaction and restores the absorption spectra characteristic for MGB and quencher in single-labeled analogs.Absorption spectra analysis of the MGB-FAM dual-labeled probe (Figure 6 nm for the free probe and moves to 494 nm with a slight increase in intensity after the duplex formation. The latter number is characteristic for FAM in the single-labeled FAM probe. The same change in the FAM absorbance is found for the fully equipped PL3 probe (Figure 6The last of the dual-labeled probes, FAM-Quencher analog (Figure 6 It appears from the data presented that all the differences in absorption spectra observed between free and hybridized probes may be explained by three types of major interactions: MGB–quencher, MGB–minor groove and MGB–FAM. In addition, the quencher seems to interact with the nucleotide sequence, via the minor groove or otherwise. Additional evidence for the strong MGB–quencher intramolecular interaction may be obtained from a comparison of absorption spectra of unhybridized probes of variable length. To eliminate the effect of nucleotide sequence on fluorescence signal, simplified oligoT probes were designed (Table 5). Two guanosine bases were introduced in the middle of the sequence to avoid frame shifting upon hybridization with complementary target. The strongest red shift in both MGB and quencher portions of spectrum is observed for the 10-mer probe (Figure 7
Background fluorescence and hybridization signals increased proportionally with probe length, with almost constant signal-to-background ratios (Table 5). However, the 10-mer probe has a hybridization signal less than half versus the 18-mer. Therefore, to maximize hybridization signal it is preferable to use probes of 16 bases and longer. If real-time PCR is the assay format, the probes require Tm relevant to PCR conditions. Fortunately this requirement goes well with MGB probes which have Tm of 60–70°C for 16–18-mers almost independent of sequence content. Mechanism of action of Pleiades probes Based on the data generated in this study we suggest a hypothetical mechanism of action of Pleiades probes (Figure 8
The second critical step in the mechanism of action is the efficient hybridization-triggered fluorescence release. It is achieved through a disruption of the MGB–quencher interaction upon probe binding to target sequence and concealment of the MGB inside the minor groove as illustrated in Figure 8 DISCUSSION Performance of a fluorogenic DNA hybridization probe can be characterized by several important parameters. The first is the degree of quenching in unhybridized probe (background fluorescence). The second factor is the fluorescence intensity after hybridization with a target (signal fluorescence). Together they can be characterized by the value of signal-to-background (S/B) ratio—the ultimate measure of assay sensitivity. Furthermore, it is crucial for some applications to keep the background fluorescence stable at any temperature of the assay. For example, post-PCR melting curve analysis is an important tool in genetic analysis (36–38); it assures specificity of target detection and allows discrimination between fully and partially matched duplexes. However, a probe that has an unstable fluorescence background due, for instance, to an intrinsic secondary structure, may generate a complicated melting profile and lead to erroneous conclusions. The third factor is the efficiency of hybridization, which depends on the probe's Tm, assay conditions and presence of secondary structures in probe or target. Secondary structure in a probe can reduce hybridization rates and result in inefficient hybridization and, consequently, low fluorescent signal. This is crucial for applications such as fast cycling PCR assays. The fourth factor is the sequence specificity of hybridization, such as the ability to discriminate single nucleotide polymorphisms. The fifth factor is the resistance to enzymatic degradation during PCR reaction. This property allows a post-PCR thermal melt analysis to be performed. The molecular beacons tested in this study demonstrated outstanding S/B ratios at low temperatures, similar to that reported in literature (1). However, at PCR relevant conditions the value of this parameter was substantially compromised. A relatively stable stem is needed to keep molecular beacon's background fluorescence low at elevated temperatures. The stem structure is also required for the improved mismatch discrimination by molecular beacons (32). However, the benefits of having this structure come at the price of reduced hybridization kinetics (8,33), which may render molecular beacons inefficient for some applications. Melting profile analysis for molecular beacons is also complicated by the presence of the stem-loop to random coil transition. In addition, substantial probe degradation is observed for molecular beacons during PCR reaction (28). MGB-Eclipse, the second type of probes compared, does not possess very low fluorescence background. The S/B ratios for these probes are only slightly better than those for corresponding non-MGB linear probes. Unstable, temperature-dependent background fluorescence is another weakness of MGB-Eclipse probes. On the upside, due to the stabilizing effect of the MGB, MGB-Eclipse probes are relatively short and, therefore, have a good mismatch discriminating ability. Another benefit is that their rates of hybridization are not inhibited by purposefully introduced secondary structures. In this and other aspects MGB-Eclipse probes are similar to no-stem PNA beacons (8). PNA beacons also demonstrate signal-to-background ratios of approximately 10–15 at room temperature and of ~7 at 43°C (39), which are similar to those of MGB-Eclipse. Also like MGB-Eclipse, short no-stem PNA beacons are more sensitive to sequence mismatches compared to longer linear DNA probes. For many applications both no-stem PNA and MGB-Eclipse probes will provide good performance.Pleiades probes combine the advantages and address some of the drawbacks of the other technologies. They possess low background fluorescence and high S/B ratios both at ambient temperature and PCR-relevant temperatures. Unlike MGB-Eclipse, Pleiades probes do not demonstrate peculiar, duplex-unrelated melting transitions. Combination of high hybridization signal with low and stable background is the basis for increased sensitivity of the Pleiades probes. In addition to providing a higher sensitivity, low background fluorescence allows the use of increased concentrations of the probes without overwhelming detection devices. Another useful feature of the Pleiades probes is that the background fluorescence, at least in part, depends on the distance (spacer length) between the MGB and the dye. This offers a way to fine tune properties of the probes, which may be desirable for certain applications. For example, the long, hexaethylene glycol spacer between branching point and fluorophore slightly raises the background fluorescence. On the other hand, this allows higher hybridization fluorescence and reduced quenching by the nucleotide sequence. This may be important for high-throughput probe design for PCR application. Alternatively, for applications, such as solid phase-immobilized light-up hybridization (40–42) or in vivo studies, a lower background and higher S/B ratios may be more beneficial. In this case shorter spacer, such as C6-spacer, should be used. Similar to MGB-Eclipse, they demonstrate fast hybridization kinetics and excellent stability against 5′->3′-exonuclease cleavage. Like all MGB-containing oligonucleotides, Pleiades probes possess excellent specificity due to their short length and the mismatch discriminating effects of the MGB (43).
ACKNOWLEDGEMENTS The authors thank Dr. Nic Vermeulen for useful discussions and Noah Scar for technical assistance. Funding to pay the Open Access publication charge was provided by Nanogen, Inc., San Diego, CA. Conflict of interest statement. None declared. REFERENCES 1. Tyagi S, Kramer FR. Molecular beacons: probes that fluoresce upon hybridization. Nat. Biotechnol. 1996;14:303–308. [PubMed] 2. Marras SAE, Kramer FR, Tyagi S. Efficiency of fluorescence energy transfer and contact-mediated quenching in oligonucleotide probes. Nucleic Acids Res. 2002;30:e122. [PubMed] 3. Whitcombe D, Theaker J, Guy SP, Brown T, Little S. Detection of PCR products using self-probing amplicons and fluorescence. Nat. Biotechnol. 1999;17:804–807. [PubMed] 4. Armitage B, Ly D, Koch T, Frydenlund H, Orum H, Schuster GB. Hairpin-forming peptide nucleic acid oligomers. Biochemistry. 1998;37:9417–9425. [PubMed] 5. Coull JM, Gildea BD, Hyldig-Nielsen JJ. 1999. Methods, kits and compositions pertaining to PNA molecular beacons. WO A-9922018. 6. Livak KJ, Flood SJA, Marmaro J, Giusti W, Deetz K. PCR Methods Appl. Vol. 4. Cold Spring Harbor Laboratory Press; 1995. Oligonucleotides with fluorescent dyes at opposite ends provide a quenched probe system useful for detecting PCR products and nucleic acid hybridization; pp. 357–362. [PubMed] 7. Livak KJ, Flood SJA, Mamoro J, Mullah KB. 2004. Hybridization assay using self-quenching fluorescence probe. US6821727 B1. 8. Kuhn H, Demidov VV, Coull JM, Fiandaca MJ, Gildea BD, Frank-Kamenetskii MD. Hybridization of DNA and PNA molecular beacons to single-stranded and double-stranded DNA targets. J. Am. Chem. Soc. 2002;124:1097–1103. [PubMed] 9. Gildea BD, Coull JM, Hyldig-Nielsen JJ, Fiandaca MJ. 1999. Methods, kits and compositions pertaining to linear beacons. WO A-9921881. 10. Seitz O. Solid-phase synthesis of doubly labeled peptide nucleic acids as probes for the real-time detection of hybridization. Angew. Chem., International Edition. 2000;39:3249–3252. 11. Johansson MK, Fidder H, Dick D, Cook RM. Intramolecular dimers: a new strategy to fluorescence quenching in dual-labeled oligonucleotide probes. J. Am. Chem. Soc. 2002;124:6950–6956. [PubMed] 12. Davies M, Bruce IM, Wolter A. US patent application. 2003. Nucleic acid probes and methods to detect and/or quantify nucleic acid analytes. 0143591 A1. 13. Ranasinghe RT, Brown LJ, Brown T. Linear fluorescent oligonucleotide probes with an acridine quencher generate a signal upon hybridization. Chem. Commun. 2001:1480–1481. 14. Yamane A. MagiProbe: a novel fluorescence quenching-based oligonucleotide probe carrying a fluorophore and an intercalator. Nucleic Acids Res. 2002;30:e97. [PubMed] 15. Kodama S, Asano S, Moriguchi T, Sawai H, Shinozuka K. Novel fluorescent oligoDNA probe bearing a multi-conjugated nucleoside with a fluorophore and a non-fluorescent intercalator as a quencher. Bioorg. Med. Chem. Lett. 2006;16:2685–2688. [PubMed] 16. Ishiguro T, Saitoh J, Yawata H, Otsuka M, Inoue T, Sugiura Y. Fluorescence detection of specific sequence of nucleic acids by oxazole yellow-linked oligonucleotides. Homogeneous quantitative monitoring of in vitro transcription. Nucleic Acids Res. 1996;24:4992–4997. [PubMed] 17. Svanvik N, Westman G, Wang D, Kubista M. Light-up probes: thiazole orange-conjugated peptide nucleic acid for detection of target nucleic acid in homogeneous solution. Anal. Biochem. 2000;281:26–35. [PubMed] 18. Kohler O, Jarikote DV, Seitz O. Forced intercalation probes (FIP): thiazole orange as a fluorescent base in peptide nucleic acids for homogeneous single-nucleotide-polymorphism detection. Chem. Bio. Chem. 2005;6:69–77. 19. Marks AH, Bhadra PK, McDowell DG, French DJ, Douglas KT, Bichenkova EV, Bryce RA. Molecular basis of action of HyBeacon fluorogenic probes: a spectroscopic and molecular dynamics study. J. Biomol. Struct. Dyn. 2005;23:49–62. [PubMed] 20. Knemeyer JP, Marme N, Sauer M. Probes for detection of specific DNA sequences at the single-molecule level. Anal. Chem. 2000;72:3717–3724. [PubMed] 21. Crockett AO, Wittwer CT. Fluorescein-labeled oligonucleotides for real-time pcr: using the inherent quenching of deoxyguanosine nucleotides. Anal. Biochem. 2001;290:89–97. [PubMed] 22. Kurata S, Kanagawa T, Yamada K, Torimura M, Yokomaku,T., Kamagata Y, Kurane R. Fluorescent quenching-based quantitative detection of specific DNA/RNA using a BODIPY((R)) FL-labeled probe or primer. Nucleic Acids Res. 2001;29:E34. [PubMed] 23. Kutyavin IV, Afonina IA, Mills A, Gorn VV, Lukhtanov EA, Belousov ES, Singer MJ, Walburger DK, Lokhov SG, et al. 3′-Minor groove binder-DNA probes increase sequence specificity at PCR extension temperatures. Nucleic Acids Res. 2000;28:655–661. [PubMed] 24. Reed MW, Lukhtanov EA, Gall AA, Dempcy RO. 2004. Fluorescent quenching detection reagents and methods. US6727356. 25. Holland PM, Abramson RD, Watson R, Gelfand DH. Detection of specific polymerase chain reaction product using the 5′ to 3′ exonuclease activity of thermus aquaticus DNA polymerase. Proc. Natl. Acad. Sci. U.S.A. 1991;88:7276–7280. [PubMed] 26. Lyamichev V, Brown MAD, Dahlberg JE. Structure-specific endonucleolytic cleavage of nucleic acids by eubacterial DNA polymerases. Science. 1993;260:778–783. [PubMed] 27. Afonina IA, Lokhov SG, Belousov YS, Reed MW, Lukhtanov EA, Shishkina IG, Gorn VV, Sanders SM, Walburger DK, et al. Hybridization-triggered fluorescence detection of DNA with minor groove binder-conjugated probes. Proc. SPIE. 2002;4626:322–331. 28. Afonina IA, Reed MW, Lusby E, Shishkina IG, Belousov YS. Minor groove binder-conjugated DNA probes for quantitative DNA detection by hybridization-triggered fluorescence. BioTechniques. 2002;32:940–944. [PubMed] 29. Lokhov S, Lukhtanov E. US Patent Application. 2005. Fluorescent probes for DNA detection by hybridization with improved sensitivity and low background. 2005/0214797 A1. 30. Reed MW, Lukhtanov EA, Gall AA, Dempcy RO, Vermeulen NMJ. 2004. Fluorescent quenching detection reagents and methods. US6790945. 31. Cantor CR, Warshaw MM, Shapiro H. Oligonucleotide interaction III. Circular dicroism studies of the conformation of deoxyoligonucleotides. Biopolymers. 1970;9:1059–1077. [PubMed] 32. Bonnet G, Tyagi S, Libchaber A, Kramer FR. Thermodynamic basis of the enhanced specificity of structured DNA probes. Proc. Natl. Acad. Sci. U.S.A. 1999;96:6171–6176. [PubMed] 33. Tsourkas A, Behlke MA, Rose SD, Bao G. Hybridization kinetics and thermodynamics of molecular beacons. Nucleic Acids Res. 2003;31:1319–1330. [PubMed] 34. Edman L, Mets U, Rigler R. Conformational transitions monitored for single molecules in solution. Proc. Natl. Acad. Sci., U.S.A. 1996;93:6710–6715. [PubMed] 35. Torimura M, Kurata S, Yamada K, Yokomaku T, Kamagata Y, Kanagawa T, Kurane R. Fluorescence-quenching phenomenon by photoinduced electron transfer between fluoresc dye and a nucleotide base. Anal. Sci. 2001;17:155–160. [PubMed] 36. Lay MJ, Wittwer CT. Real-time fluorescence genotyping of factor V Leiden during rapid-cycle PCR. Clin. Chem. 1997;43:2262–2267. [PubMed] 37. Wittwer CT, Herrmann MG, Gundry CN, Elenitoba-Johnson KSJ. Real-time multiplex PCR assays. Methods. 2001;25:430–442. [PubMed] 38. Afonina IA, Belousov YS, Metcalf M, Mills A, Sanders S, Walburger DK, Mahoney W, Vermeulen NMJ. Single nucleotide polymorphism detection with fluorescent MGB MGB-Eclipse probe systems. In: Bustin SA, editor. A-Z of Quantitative PCR. La Jolla, California: International University Line La Jolla, California; 2004. pp. 719–731. 39. Kuhn H, Demidov VV, Gildea BD, Fiandaca MJ, Coull JC, Frank-Kamenetskii MD. PNA beacons for duplex DNA. Antisense Nucleic Acid Drug Dev. 2001;11:265–270. [PubMed] 40. Fang X, Liu X, Schuster S, Tan W. Designing a novel molecular beacon for surface-immobilized DNA hybridization studies. J. Am. Chem. Soc. 1999;121:2921–2922. 41. Wang H, Li J, Liu H, Liu Q, Mei Q, Wang Y, Zhu J, He N, Lu Z. Label-free hybridization detection of a single nucleotide mismatch by immobilization of molecular beacons on an agarose film. Nucleic Acids Res. 2002;30:e61. [PubMed] 42. Ramachandran A, Flinchbaugh J, Ayoubi P, Olah GA, Malayer J. Target discrimination by surface-immobilized beacons designed to detect. Francisella tularensis. Biosens. Bioelectron. 2004;19:727–736. 43. Kutyavin I, Lokhov S, Lukhtanov E, Reed MW. Chemistry of minor groove binder – oligonucleotide conjugates. Current Protocols in Nucleic Acid Chemistry, John Wiley & Sons, Inc., Hoboken, NJ. 2003:8.4.1–8.4.21. |
PubMed related articles
Your browsing activity is empty. Activity recording is turned off. |
|||||||||||||||||||||||||||
Nat Biotechnol. 1996 Mar; 14(3):303-8.
[Nat Biotechnol. 1996]Nucleic Acids Res. 2002 Nov 1; 30(21):e122.
[Nucleic Acids Res. 2002]Nat Biotechnol. 1999 Aug; 17(8):804-7.
[Nat Biotechnol. 1999]Biochemistry. 1998 Jun 30; 37(26):9417-25.
[Biochemistry. 1998]PCR Methods Appl. 1995 Jun; 4(6):357-62.
[PCR Methods Appl. 1995]Nucleic Acids Res. 1996 Dec 15; 24(24):4992-7.
[Nucleic Acids Res. 1996]Anal Biochem. 2000 May 15; 281(1):26-35.
[Anal Biochem. 2000]J Biomol Struct Dyn. 2005 Aug; 23(1):49-62.
[J Biomol Struct Dyn. 2005]Anal Chem. 2000 Aug 15; 72(16):3717-24.
[Anal Chem. 2000]Anal Biochem. 2001 Mar 1; 290(1):89-97.
[Anal Biochem. 2001]Nucleic Acids Res. 2000 Jan 15; 28(2):655-61.
[Nucleic Acids Res. 2000]Proc Natl Acad Sci U S A. 1991 Aug 15; 88(16):7276-80.
[Proc Natl Acad Sci U S A. 1991]Science. 1993 May 7; 260(5109):778-83.
[Science. 1993]Biotechniques. 2002 Apr; 32(4):940-4, 946-9.
[Biotechniques. 2002]Biopolymers. 1970; 9(9):1059-77.
[Biopolymers. 1970]Proc Natl Acad Sci U S A. 1999 May 25; 96(11):6171-6.
[Proc Natl Acad Sci U S A. 1999]Nucleic Acids Res. 2003 Feb 15; 31(4):1319-30.
[Nucleic Acids Res. 2003]J Am Chem Soc. 2002 Feb 13; 124(6):1097-103.
[J Am Chem Soc. 2002]J Am Chem Soc. 2002 Jun 19; 124(24):6950-6.
[J Am Chem Soc. 2002]Nucleic Acids Res. 2002 Nov 1; 30(21):e122.
[Nucleic Acids Res. 2002]Proc Natl Acad Sci U S A. 1996 Jun 25; 93(13):6710-5.
[Proc Natl Acad Sci U S A. 1996]Anal Sci. 2001 Jan; 17(1):155-60.
[Anal Sci. 2001]Clin Chem. 1997 Dec; 43(12):2262-7.
[Clin Chem. 1997]Methods. 2001 Dec; 25(4):430-42.
[Methods. 2001]Nat Biotechnol. 1996 Mar; 14(3):303-8.
[Nat Biotechnol. 1996]Proc Natl Acad Sci U S A. 1999 May 25; 96(11):6171-6.
[Proc Natl Acad Sci U S A. 1999]J Am Chem Soc. 2002 Feb 13; 124(6):1097-103.
[J Am Chem Soc. 2002]Nucleic Acids Res. 2003 Feb 15; 31(4):1319-30.
[Nucleic Acids Res. 2003]Biotechniques. 2002 Apr; 32(4):940-4, 946-9.
[Biotechniques. 2002]J Am Chem Soc. 2002 Feb 13; 124(6):1097-103.
[J Am Chem Soc. 2002]Antisense Nucleic Acid Drug Dev. 2001 Aug; 11(4):265-70.
[Antisense Nucleic Acid Drug Dev. 2001]Nucleic Acids Res. 2002 Jun 15; 30(12):e61.
[Nucleic Acids Res. 2002]