Figure 2. From: Optoacoustic imaging of the prostate: development toward image-guided biopsy.

Images of combined OA signals for 1-mm cylindrical tube (with the tube axis oriented orthogonal to the imaging plane) positioned at various depths within the aqueous medium simulating optical properties of background tissues, and illuminated using (a) backward OA mode and (b) forward OA mode. OA signals were acquired using a single target, and the images were subsequently created after combining the signals from each individual acquisition. The images are displayed using the standard 8-bit gray-scale palette. The axes are scaled in millimeters.

Mohammad A. Yaseen, et al. J Biomed Opt. 2010 March-April;15(2):021310.
2.
Figure 1

Figure 1. From: Optoacoustic imaging of the prostate: development toward image-guided biopsy.

(a) Commercial 128-channel endocavity ultrasound probe (EC7ART, Scanhead Corp., San Jose, California) used to collect acoustic transients for OA imaging. The piezoceramic detectors are oriented as a convex array lining the edge of the probe, as seen in the enlarged section. (b) Measured OA impulse response of a single detector in the endocavity probe, where the dashed line indicates envelope-detected signal used for estimation of the radial resolution (see text) and (c) the corresponding frequency response.

Mohammad A. Yaseen, et al. J Biomed Opt. 2010 March-April;15(2):021310.
3.
Figure 4

Figure 4. From: Optoacoustic imaging of the prostate: development toward image-guided biopsy.

(a) Photograph of the sliced dog prostate showing the presence of the induced lesion with blood in the right lateral lobe, the urethra is visible but contracted after surgical excision; (b) ultrasonic image of the same dog prostate obtained in vivo after the surgery. OA images of the same dog prostate obtained in vivo (c) before and (d) after the lesion was induced. The induced bloody lesion can be seen in (a) and (d). The needle insertion path is visible in (a) and (b). Due to the acoustic mismatch between tissue and air, the prostate capsule can be identified in OA images as a white band. Arrows indicate the prostate capsule (PC), urethra (U), needle insertion path (NIP), and lesion (L). The images are displayed using the standard 8-bit gray-scale palette.

Mohammad A. Yaseen, et al. J Biomed Opt. 2010 March-April;15(2):021310.
4.
Figure 3

Figure 3. From: Optoacoustic imaging of the prostate: development toward image-guided biopsy.

Comparison of the modeled OA image with the image acquired in vivo: (a) imaging slice showing the distribution of the absorbed optical energy in a prostate model with spherical malignant lesion, determined by MC simulation; (b) OA image constructed using the simulated acoustic transients and the RBP algorithm; and (c) OA image of the dog prostate obtained in vivo after inducing a blood-rich lesion. The prostate capsule can be delineated in the OA images. The urethra and the lesion can be seen in the OA images as a dark and bright spots, respectively. The absorption difference between the lesion and surrounding tissue results in high contrast of the OA image. The low absorption in the urethra yields low OA signals. On each image, arrows indicate the prostate capsule (PC), urethra (U), and lesion (L). The images are displayed using the standard 8-bit gray-scale palette.

Mohammad A. Yaseen, et al. J Biomed Opt. 2010 March-April;15(2):021310.